1. As the draining is of natural drain type, make the drain hose direct
downward.
2. If there is any foreign substance in the drain plate, it may clog the
drain pipe.
Therefore, be sure to remove the foreign substance inside after
installation.
3. After completion of installation, be sure to pour water into the drain
pan, and then check the draining condition.
(There is no problem in draining when the draining is completed with-
in 20 seconds.)
Operating Instructions and Installation
3-13
Piping
Material
Insulator
Vinyl Chloride(Inner diameter ø18mm,
Outer diameter ø 23mm)
Foamed Polyethylene
Caution
3-2-3(e) Drilling a Hole in the Wall
• Drill a hole of 60mm in diameter to the outside.
• The drilling should be done at a distance of less than
150mm from the floor facing the indoor unit.
3-2-3(f) Drain Hosel
•
Extend the drain hose to the drain hose connected to the
drain pan, and fix it with the tape or a cable tie to pre v e n t
separation. Then make a covering of it so that water can
not flow outward l y.
•
In heating and deice operation, condensed water may
be generated.
Install drain line as gollowing pro c e d u re .
1. Insert the drain plug into drain hole.
2. And then connect drain hose to drain plug.
3 - 2 - 3 ( g )
•
The piping of this unit can be connected to the right,
left, and rear side. When you hit the area for piping
connection slightly with a hammer, a hole is made.
•
After connecting the piping and drain hose, insert the
rubber cap as shown in the figure below.
Less than
150mm
Hole
Base
Drain plug
Drain hose
Holes for piping connection (3 points)
ø60mm
Summary of Contents for KFH28PV2
Page 4: ...2 2 2 2 Dimensions Indoor Unit Outdoor Unit unit mm 330...
Page 26: ...Disassembly and Reassembly 4 5 No Parts Procedur e Remark...
Page 35: ...6 1 6 Exploded Views and Parts List 6 1 Indoor Unit...
Page 37: ...6 3 6 1 1 ASS Y COVER FRONT Exploded Views and Parts List...
Page 39: ...6 5 6 1 2 ASS Y GRILLE INLET Exploded Views and Parts List...
Page 41: ...6 7 6 2 Outdoor unit 19 18 14 1 16 17 15 7 6 9 11 13 12 8 2 4 5 19 1 19 2 10 3...
Page 46: ...8 1 8 PCB Diagrams 8 1 Ass y Main PCB CODE NO DB93 10531B...
Page 48: ...8 3 8 2 Ass y Power PCB Code No DB93 10532B...
Page 51: ...9 1 9 Wiring Diagrams 9 1 Indoor Unit...
Page 52: ...9 2 9 2 Outdoor Unit...
Page 54: ...10 1 10 Schematic Diagrams 10 1 Indoor Unit...
Page 55: ...10 2 10 2 Remote Control...