Operating Instructions and Installation
3-12
3-2-3(d) Connection of refrigerant pipe
1 . Cut the pipe using the pipe cutter.
2. Insert the flare nut into the pipe, and then perform the flare pro c e s s i n g .
•
Align the center of the connection piping, and tighten
the flare nut by turning it with hand. Then tighten it
again using the spanner in the direction as shown in
the figure .
1 . Perform bending of the pipe using the bender which has
a specified bending radius.
2 . Be sure to take full care to perform bending of the pipe
successfully at one time. Bending and unbending the pipe
m o re than twice makes the bending work incre a s i n g l y
d i ff i c u l t .
3 . You may use the spring inserted into the gas pipe instead
of the bender to bend the pipe.
4 . When you bend the pipe using the spring, hold the pipe
with both hands to prevent any distortion, and secure a
minimum bending radius of more than 100mm.
Flare Processing
Pipe Bending
Tightening of Connection Parts
Spring
Oblique
Roughness
Burr
Outer Diameter
ø 6.35 mm
ø 9.52 mm
ø 15.8 mm
A
1.3
1.8
2.0
Final Torque
200kg • cm
450 kg • cm
750 kg • cm
Remarks
Outer Diameter
ø 6.35mm
ø 9.52mm
ø 15.8mm
Tightening Torque
160 kg • cm
400 kg • cm
700 kg • cm
Summary of Contents for KFH28PV2
Page 4: ...2 2 2 2 Dimensions Indoor Unit Outdoor Unit unit mm 330...
Page 26: ...Disassembly and Reassembly 4 5 No Parts Procedur e Remark...
Page 35: ...6 1 6 Exploded Views and Parts List 6 1 Indoor Unit...
Page 37: ...6 3 6 1 1 ASS Y COVER FRONT Exploded Views and Parts List...
Page 39: ...6 5 6 1 2 ASS Y GRILLE INLET Exploded Views and Parts List...
Page 41: ...6 7 6 2 Outdoor unit 19 18 14 1 16 17 15 7 6 9 11 13 12 8 2 4 5 19 1 19 2 10 3...
Page 46: ...8 1 8 PCB Diagrams 8 1 Ass y Main PCB CODE NO DB93 10531B...
Page 48: ...8 3 8 2 Ass y Power PCB Code No DB93 10532B...
Page 51: ...9 1 9 Wiring Diagrams 9 1 Indoor Unit...
Page 52: ...9 2 9 2 Outdoor Unit...
Page 54: ...10 1 10 Schematic Diagrams 10 1 Indoor Unit...
Page 55: ...10 2 10 2 Remote Control...