Installation Instructions
The appliance must be installed by authorised personnel in accordance to the
manufacturer ’s instructions and local regulations.
This appliance must be installed in accordance with:
AS/NZS 5601 - Gas Installations (for Australia)
NZS 5261 – Code of Practice for the Installation of Gas Burning Appliances and
Equipment (for New Zealand)
Local gas fitting regulations
AS/NZS 3000 – Electrical Installations (Wiring Rules)
Building codes
Installation environment
The gas appliance shall be installed such that the surface temperature of any nearby
combustible surface will not exceed 65°C above ambient. If there is insufficient space or
natural air flow to meet this requirement, creating an air gap between a heat shield and/or
insulating material and the combustible substrate may be effective. Care should be taken
where a combustible surface is covered by a non-combustible material. For example,
covering a combustible surface with stainless steel may not prevent heat transfer and in
some circumstances a hazardous situation could arise.
The materials used in the adjacent cabinets is to be able to withstand a temperature of 90°C
or higher. Combustible materials, such as curtains, must be at the minimum distance of
500mm. Refer to the diagram below, any vertical combustible surface, A, which is less than
200mm measured from the periphery of the nearest burner, must have either
i.B of not less than 150mm above the periphery of the nearest burner for full dimension
(width or depth) of the cooking surface area, OR
ii.C of 10mm or more.
The distance between the highest part of the highest burner of the cooker and a
i.Exhaust fan is 750mm
ii.Range hood is 600mm
Diagram below shows the requirements and product dimension.
Page 5