GL0052-03
– Envireau Mono-Tech Rainwater – Installation & Operation Guidelines
Page 29
PUMP & PLUMBING DETAILS
DIRECT SYSTEM
DIRECT SYSTEM
RAINWATER RECOVERY
DIRECT SYSTEM
SCHEMATIC WIRING RUNS
1) Always secure the pump in a vertical position, but do not suspend. Use the lifting rope to lower and secure.
2) Make certain all joints are secure. Do not overtighten any fittings.
systemdirect-02
DIAGRAM A
1) Check your invert levels in advance, particularly if using a leaf filter.
2) Make sure that no surface water or debris enters the tank during installation.
3) Do not fix the Tundish device above electrical equipment.
4) Try to take the mains water supply from the furthest system point to avoid diverting when topping-up the outside tank.
1) Make duct suitable for free drawing of cables.
2) If you must join cables, joint out of the turret. Joints should be completely watertight.
3) Do not take oversized cables into the controller. Use joint boxes to change to suitable cables. See installation details for suitable cables.
4) Earth bond the solenoid valve by using the earth connection in the control unit.
DIAGRAM B
DIAGRAM C
Direct System Guide Sheet