ENG
20
19
Humidifier Tank
When the humidifier water tank is removed from the body of the unit the
power automatically shuts off.
CLEANING
Always unplug the unit before servicing in any way.
CLEANING
Inside the base of the unit.
Pour excess water out of the unit. Wash out the
unit with fresh water using the cleaning brush and a soft cloth as needed.
Do
not submerse the base of the unit into water, or allow water to enter inside
the dry air exhaust port of the unit.
Water tank.
Empty water tank. Remove mist nozzle and clean the mist tube
with fresh water and a light brush (bottle cleaning brush is recommended).
Outer surface of the unit.
Wipe the surface of the unit with a soft, damp
cloth if needed. If you notice an accumulation of water during usage, reduce
humidity and dry outer surface with a cloth.
GENERAL CLEANING
1.Unplug unit.
2.Remove the tank and empty all water from unit base and tank.
3.Locate the ultrasonic disk on the inside center of the base unit.
4.Use ONLY the enclosed cleaning brush to gently clean disk and remove build
up and deposits.
ULTRASONIC DISK
Do not scrub or scrape the ultrasonic disk.
*
cleaning tool should be used.
BRUSH ONLY.
Clean the disk with the brush only. No other
Ultrasonic Disk
If scale becomes difficult to remove with brush:
1.Fill the Base with: mixture of 1 tsp. white vinegar and 1 tsp. Water.
2.Let solution stand for 5 minutes.
3.With the vinegar in the Base, clean all interior surfaces with a soft cloth or
brush to help remove scale.
4.Also check mist nozzle and mist tube in water tank. Clean as needed.
5.Rinse the Base thoroughly with water to remove scale and vinegar solution.
Are minerals in your water producing white dust?
Try our Decalcification Cartridge
END OF SEASON STORAGE
Follow the Cleaning and Descaling instructions when the humidifier will be
stored at the end of the season.
Dry the humidifier completely before storing. DO NOT store with water inside
the Base or Water Tank.
Pack the unit in its original carton and store in a cool, dry location.
NOTE: IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE
MOTOR HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND
CAUSE DAMAGE TO THE HUMIDIFIER OR PERSONAL INJURY.
TROUBLESHOOTING GUIDE
PROBLEM
SOLUTION
Water vapor and
humidity are not
produced.
Power plug: Unplug and then try again.
Power Failure: When the power is returned, try again. Tank
Installation: Make sure the tank is correctly attached. The
surface of the ultrasonic disk is dirty: Clean ultrasonic disk.