IMPORTANT SAFETY INFORMATION 

This section contains important safety information for the 

KISAE Abso Charger

. Each time, before 

using the unit, READ ALL instructions and cautionary markings on or provided with the unit, and all 
appropriate sections of this guide. The 

KISAE Abso Charger

 contains no user-serviceable parts. 

See Warranty section for how to handle product issues. 

 

WARNING: Fire and/or Chemical Burn Hazard!  

Do not cover or obstruct any air vent openings and/or install in a zero-clearance compartment.  

WARNING: Failure to follow these instructions can result in death or serious injury. Keep away 
from children!

 

 

When working with electrical equipment or lead acid batteries, have someone nearby in case of an 
emergency. 

 

Study  and  follow  all  the  battery  manufacturer’s  specific  precautions  when  installing,  using  and 
servicing the battery connected to the charger.  

 

Wear eye protection and gloves. 

 

Avoid touching your eyes while using this unit. 

 

Keep fresh water and soap on hand in the event battery acid comes in contact with eyes. If this 
occurs,  cleanse  right  away  with soap  and  water  for  a minimum  of 15  minutes  and  seek medical 
attention. 

 

Batteries produce explosive gasses. 

DO NOT 

smoke or have an open spark or fire near the system. 

 

Keep the unit away from moist or damp areas. Never expose the unit to snow, water etc. 

 

Avoid dropping any metal tool or object on the battery. Doing so could create a spark or short circuit 
which goes through the battery or another electrical tool that may create an explosion. 

WARNING: Explosion hazard!

 

 

Do not use the unit in the vicinity of flammable fumes or gasses (such as propane tanks or large 
engines). 

 

Avoid covering the ventilation openings. Always operate the unit in an open area. 

 

Prolonged contact with high heat or freezing temperatures will decrease the working life of the unit. 

CAUTION:

 

 

This appliance is not intended for use by persons (including children) with reduced physical, sensory 
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a person responsible for their safety. 

 

Children should be supervised to ensure that they do not play with the appliance. 

 

Do not charge non-rechargeable batteries because of the danger of eruption. 

 

During charging, the batteries have to be placed in a ventilated area. 

 

The battery terminal not connected to the chassis has to be connected first. 

 

The other connection is to be made to the chassis, remote from the battery and fuel line. The battery 
charger is then to be connected to the supply mains. 

 

After  charging,  disconnect  the  battery  charger  from  the  supply  mains. Then  remove  the  chassis 
connection and then the battery connection. 

 

Only allow children at least 8 years old to use the battery charger. Give sufficient instruction so that 
the child is able to use the battery charger in a safe way and explain that it is not a toy and must not 
be played with. 

 

The child does not try to charge non-rechargeable batteries because of the danger of eruption. 

 

Examine the battery charger regularly for damage, especially the cord,  plug, and enclosure. If the 
battery charger is damaged, it must not be used until it has been repaired. 

 
 

 

Summary of Contents for Abso Charger 12V 100A

Page 1: ...Abso Charger 12V 100A AC12100 24V 50A AC2450 Owner s Manual...

Page 2: ...Page 2...

Page 3: ...Abso Charger Misuse may result in damage to the unit and or cause harm or serious injury Product Numbers AC12100 Abso Charger 12V 100A AC2450 Abso Charger 24V 50A Document Part Number MU AC12100 Rev...

Page 4: ...STALLING THE CHARGER 10 5 UNIT OPERATION 13 6 SPECIFICATIONS 19 7 WARRANTY 20 Appendix A1 GEL Flooded AGM Setting CH1 CH2 CH3 Appendix A2 1 Lithium Setting CH1 Appendix A2 2 Lithium Setting CH2 3 Appe...

Page 5: ...an explosion WARNING Explosion hazard Do not use the unit in the vicinity of flammable fumes or gasses such as propane tanks or large engines Avoid covering the ventilation openings Always operate th...

Page 6: ...ere is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning...

Page 7: ...lgorithm During normal operation the charger will do a full charge cycle to float stage on Battery Bank 1 Once the float stage is reached the charger starts charging Battery Banks 2 and 3 together wit...

Page 8: ...Battery Bank 3 Chassis Ground The unit chassis has to be grounded properly to the common ground point on the system Digital Remote optional The Display Remote Part Number ACRM1202 sold separately is...

Page 9: ...e battery voltage reaches approximately 13 5V This timer is set to avoid battery overcharging The charger will override the Absorption to Float stage condition and goes to Float stage when it times ou...

Page 10: ...he mounting template on the right to mark the positions of the mounting screws Drill the 4 mounting holes and place the Charger in position and fasten the unit to the mounting surface See mounting loc...

Page 11: ...screws located at the top of the AC compartment cover Remove the top section of the AC Input wire strain relief located at the bottom of the base panel inside the AC wiring compartment by unscrewing t...

Page 12: ...s Remote Port to the COM_2 port on the Remote Display Panel The Remote Display Panel is now ready to use Both charger displays will show CON indicating the chargers are connected in parallel And all...

Page 13: ...display will then show the next menu to continue with other setting parameters NEXT Press the hold the key for longer than 5 seconds to RESET the charger Display will show RST and it will force the ch...

Page 14: ...27 V 0 54V AGM 0 21 V 0 42V For use when Battery Temperature Sensor is in use No setting on the unit is required and the unit will automatically sense the Battery Temperature Sensor when it is connec...

Page 15: ...rent L current in A Charging stages CH1 only Mode 2 Bulk and Absorption stage only Mode 3 Bulk Absorption and Float stage Battery temperature CH1 only Low Lo Normal nor High hi For Lithium battery typ...

Page 16: ...ed channel first and follows with 1 hour of 15 5V equalization process Consult or follow the instruction as provided by the battery manufacturer on how to check the battery electrolyte level and or re...

Page 17: ...g code will display The charger will recover automatically back to the maximum charging current when the environmental temperature drops to below 45 C Over Temperature Shutdown When the charger senses...

Page 18: ...alled The unit will shut down The unit will automatically recover when the battery temperature has reduced to 60 C 140 F For Lithium battery type setting High battery temperature 60 C 140 F is sensed...

Page 19: ...ith back lighting Charging status Battery Voltage Warning and Fault Code A01 E01 09 AC Input and DC Output Connection AC Input Connection Hardwire or AC with EU UK AZ plug DC Output Connection POS Hea...

Page 20: ...ive if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to the manufacturer...

Page 21: ...Page 21...

Page 22: ...Page 22...

Page 23: ...Page 23...

Page 24: ...Page 24...

Page 25: ...Page 25...

Page 26: ...Page 26 Appendix B...

Reviews: