Mode 2 Charging:  

The Two-Stage mode 2 charging is similar to the Three-Stage charging except that there is no 

Float

 

stage after the 

Absorption

 stage. The charger will terminate the battery charging after Absorption 

stage.  
The charger will automatically restart the full charging cycle if it senses any one of the battery banks 
is discharged to lower than 12.5V for the 12V model, 25.0V for the 24V model, or after seven days 
since the last Absorption stage to refresh the battery banks.   

Understanding the Battery Temperature Set Functions: 

For use when Battery Temperature Sensor is 

NOT

 in use: 

CAUTION: RISK OF BATTERY DAMAGE. 

If the temperature sensor is not being used, never set 

the battery temperature lower than the actual temperature. This may 

overcharge and damage

 the 

batteries. 

There  are  three  manual  battery  temperature  settings  available  on  the  unit  for  GEL,  Flooded  and 
AGM batteries.  

 

Low temperature ‘Lo’, setting for when the battery is charging in a low temperature environment. 

 

Normal temperature ‘nor’, setting is for when the battery is charging at room temperature. 

 

High  temperature  ‘HI’,  setting  is  for  when  the  battery  is  charging  in  a  high  temperature 
environment.  

With different settings above, the battery charging voltage is adjusted as listed below. 

Temperature 

Setting 

Recommended 

for Battery 

Temperature 

Battery Type 

Voltage adjustment from 25°C 

normal setting 

12 V model 

24 V model 

Low (Lo) 

<5°C 

(41°F) 

GEL, Flooded 

+ 0.675 V 

+ 1.350 V 

AGM 

+ 0.525 V 

+ 1.050 V 

Normal (nor) 

>5°C and <30°C 

(>41°F and <86°F) 

GEL, Flooded 

0 V 

0 V 

AGM 

0 V 

0 V 

High (HI) 

>30°C 
(86°F) 

GEL, Flooded 

- 0.27 V 

- 0.54V 

AGM 

- 0.21 V 

- 0.42V 

For use when Battery Temperature Sensor is in use: 

No  setting  on  the  unit  is  required,  and  the  unit  will  automatically  sense  the  Battery  Temperature 
Sensor when it is connected to the BTS Port and the manual battery temperature setting on the unit 
will be over-ridden by having the Battery Temperature installed.   

 

Use with GEL, AGM, or Flooded Battery Type Setting:  

The  battery  sensor  installed  on  Battery  Bank  1  will  monitor  the  Battery  Bank  1  battery 
temperature and will make small adjustments to the battery charging voltage on CH1 for better 
battery charging performance.  

Battery 

Temperature 

Battery Charging Voltage Adjustment from 25 °C normal setting 

Flooded and GEL type 

AGM type 

12 V Model 

24 V Model 

12 V Model 

24 V Model 

< 25 °C 

+ 0.027 V /°C 

+ 0.054 V / °C 

+ 0.021 V /°C 

+ 0.042 V /°C 

25 °C 

0 V 

0 V 

0 V 

0 V 

> 25 °C 

- 0.027 V /°C 

- 0.054 V /°C 

- 0.021 V /°C 

- 0.042 V /°C 

The sensor is also used to terminate the battery charging process when the battery temperature 
drops to below -25°C and the charging process will resume again when battery temperature rises 
to above -20°C. It will also terminate the charging process when the battery temperature rises to 
above 70°C and the charging process will resume again when the battery temperature drops to 
below 60°C. 

 

Use with Lithium or Program Setting: 

The  battery  sensor  installed  on  Battery  Bank  1  will  monitor  the  Battery  Bank  1  battery 
temperature. It is used to terminate the battery charging process when the battery temperature 
drops to below 0°C. The charging process will resume again when battery temperature rises to 
above 5°C.  It will  also terminate  the  charging process  when the  battery temperature  rises to 
above 60°C and the charging process will resume again when the battery temperature drops 
to below 55°C. 

 

 

Summary of Contents for Abso Charger 12V 100A

Page 1: ...Abso Charger 12V 100A AC12100 24V 50A AC2450 Owner s Manual...

Page 2: ...Page 2...

Page 3: ...Abso Charger Misuse may result in damage to the unit and or cause harm or serious injury Product Numbers AC12100 Abso Charger 12V 100A AC2450 Abso Charger 24V 50A Document Part Number MU AC12100 Rev...

Page 4: ...STALLING THE CHARGER 10 5 UNIT OPERATION 13 6 SPECIFICATIONS 19 7 WARRANTY 20 Appendix A1 GEL Flooded AGM Setting CH1 CH2 CH3 Appendix A2 1 Lithium Setting CH1 Appendix A2 2 Lithium Setting CH2 3 Appe...

Page 5: ...an explosion WARNING Explosion hazard Do not use the unit in the vicinity of flammable fumes or gasses such as propane tanks or large engines Avoid covering the ventilation openings Always operate th...

Page 6: ...ere is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning...

Page 7: ...lgorithm During normal operation the charger will do a full charge cycle to float stage on Battery Bank 1 Once the float stage is reached the charger starts charging Battery Banks 2 and 3 together wit...

Page 8: ...Battery Bank 3 Chassis Ground The unit chassis has to be grounded properly to the common ground point on the system Digital Remote optional The Display Remote Part Number ACRM1202 sold separately is...

Page 9: ...e battery voltage reaches approximately 13 5V This timer is set to avoid battery overcharging The charger will override the Absorption to Float stage condition and goes to Float stage when it times ou...

Page 10: ...he mounting template on the right to mark the positions of the mounting screws Drill the 4 mounting holes and place the Charger in position and fasten the unit to the mounting surface See mounting loc...

Page 11: ...screws located at the top of the AC compartment cover Remove the top section of the AC Input wire strain relief located at the bottom of the base panel inside the AC wiring compartment by unscrewing t...

Page 12: ...s Remote Port to the COM_2 port on the Remote Display Panel The Remote Display Panel is now ready to use Both charger displays will show CON indicating the chargers are connected in parallel And all...

Page 13: ...display will then show the next menu to continue with other setting parameters NEXT Press the hold the key for longer than 5 seconds to RESET the charger Display will show RST and it will force the ch...

Page 14: ...27 V 0 54V AGM 0 21 V 0 42V For use when Battery Temperature Sensor is in use No setting on the unit is required and the unit will automatically sense the Battery Temperature Sensor when it is connec...

Page 15: ...rent L current in A Charging stages CH1 only Mode 2 Bulk and Absorption stage only Mode 3 Bulk Absorption and Float stage Battery temperature CH1 only Low Lo Normal nor High hi For Lithium battery typ...

Page 16: ...ed channel first and follows with 1 hour of 15 5V equalization process Consult or follow the instruction as provided by the battery manufacturer on how to check the battery electrolyte level and or re...

Page 17: ...g code will display The charger will recover automatically back to the maximum charging current when the environmental temperature drops to below 45 C Over Temperature Shutdown When the charger senses...

Page 18: ...alled The unit will shut down The unit will automatically recover when the battery temperature has reduced to 60 C 140 F For Lithium battery type setting High battery temperature 60 C 140 F is sensed...

Page 19: ...ith back lighting Charging status Battery Voltage Warning and Fault Code A01 E01 09 AC Input and DC Output Connection AC Input Connection Hardwire or AC with EU UK AZ plug DC Output Connection POS Hea...

Page 20: ...ive if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to the manufacturer...

Page 21: ...Page 21...

Page 22: ...Page 22...

Page 23: ...Page 23...

Page 24: ...Page 24...

Page 25: ...Page 25...

Page 26: ...Page 26 Appendix B...

Reviews: