Understanding and Procedure to Set or View CH1 or CH2 and CH3 setting:  

The following table shows the preset values of the battery charging voltage on 

GEL

Flooded

 and 

AGM

 type and the user selectable battery voltage setting for the 

Lithium

 and 

Program

 type. 

AC12100 

Battery Type 

Absorption 

Float 

Equalization 

GEL 

14.4 V 

13.7 V 

N.A. 

AGM 

14.7 V 

13.6 V 

N.A. 

Flooded 

14.4 V 

13.3 V 

15.5 V 

Lithium 

13.9 

– 14.8 V (0.1V step) 

13.0 

– 13.9 V (0.1V step) 

N.A 

Program  

13.8 

– 14.8 V (0.1V step) 

13.0 

– 13.8 V (0.1V step) 

N.A 

Note 1: Manufacturing default setting on Lithium Battery/Program type is 14.4V (Abs) and 13.5V (Flo)  
Note 2: All the above voltage will be double on 24V charger AC2450.  

The  following  table  shows  the  maximum  available  charging  current  and  its  related  available 
Absorption to Float stage current.  

Model 

Maximum 

Current 

Setting (CH1) 

Absorption to Float 

Stage Current 

Setting (CH1) 

Maximum 

Current  

Setting (CH2/3) 

Absorption to Float 

Stage Current 

Setting (CH2/3) 

AC 12100

 

* 100A 

* 4A / 8A / 12A 

60A 

3A / 6A / 12A 

60A 

3A / 6A / 12A 

40A 

2A / 4A / 8A 

40A 

2A / 4A / 8A 

20A 

1A / 2A / 4A 

20A 

1A / 2A / 4A 

10A 

0.5A/ 1.0A/ 2.0A 

AC 2430 

* 50A 

* 2A / 4A / 8A 

50A 

* 2A / 4A / 8A 

30A 

2A / 3A / 6A 

30A 

2A / 3A / 6A 

20A 

1A / 2A / 4A 

20A 

1A / 2A / 4A 

10A 

0.5A / 1A / 2A 

10A 

0.5A / 1A / 2A 

Note: * Recommended setting (Factory Default Setting)

  

For GEL, AGM, Flooded battery type: (Appendix A1)

 

  Battery type (

GEL, AGM, Flooded, Program

  Maximum charging current (

h-current

’ in A) 

  Absorption to float stage current (

L-current

’ in A) 

  Charging stages (CH1 only) 

Mode 2

 

– Bulk and Absorption stage only, 

Mode 3

 

– Bulk, Absorption, 

and Float stage) 

  Battery temperature (CH1 only) (Low- 

Lo

’, Normal – ‘

no

r

’, High – ‘

hi

’) 

For Lithium battery type: (Appendix A2.1, A2.2)  

WARNING:

 FIRE HAZARD! When using the 

Lithium

 mode to set the battery Charging parameters, 

please consult the battery manufacturer on all voltage and current settings. Using wrong setting to 
charge a Lithium battery may overcharge and damage the  battery, resulting in battery explosion 
and fire.  

  Battery type (

Lithium

  Maximum Charging Voltage (CV-

‘Abs’) (13.9-14.8V for 12V model, 27.8-29.6V for 24V model) 

  Absorption to Float 

Voltage (‘FLo’) (13.0-13.8V for 12V model, 26.0-27.6V for 24V model) 

  Maximum Charging Current (CC) (

h-current

’ in A) 

  Absorption to Float Current (Charge termination current) (

L-current

’ in A) 

  Charging  stages  -  CH1  only  (

Mode  2

 

–  Bulk  and  Absorption  stage  only, 

Mode  3

 

–  Bulk, 

Absorption, and Float stage)  

For Program type: (Appendix A3.1, A3.2) 

WARNING:

 FIRE HAZARD! When using the 

Program

 mode to set the battery charging parameters, 

please consult the battery manufacturer on all voltage and current settings. Using a wrong setting 
to charge the battery may overcharge and damage the battery, resulting in battery explosion and 
fire. 

  Battery type (

Program

 

Absorption Voltage (‘Abs’) (13.9 - 14.8V for 12V model, 27.8 - 29.6V for 24V model) 

  Absorption to Float 

Voltage (‘FLo’) (13.0 - 13.8V for 12V model, 26.0 - 27.6V for 24V model) 

  Maximum Bulk Current (

h-current

’ in A) 

  Absorption to Float Current (

L-current

’ in A) 

  Charging stages - CH1 only (

Mode 2

 

– Bulk and Absorption stage, 

Mode 3

 

– Bulk, Absorption, 

and Float stage) 

 

 

Summary of Contents for Abso Charger 12V 100A

Page 1: ...Abso Charger 12V 100A AC12100 24V 50A AC2450 Owner s Manual...

Page 2: ...Page 2...

Page 3: ...Abso Charger Misuse may result in damage to the unit and or cause harm or serious injury Product Numbers AC12100 Abso Charger 12V 100A AC2450 Abso Charger 24V 50A Document Part Number MU AC12100 Rev...

Page 4: ...STALLING THE CHARGER 10 5 UNIT OPERATION 13 6 SPECIFICATIONS 19 7 WARRANTY 20 Appendix A1 GEL Flooded AGM Setting CH1 CH2 CH3 Appendix A2 1 Lithium Setting CH1 Appendix A2 2 Lithium Setting CH2 3 Appe...

Page 5: ...an explosion WARNING Explosion hazard Do not use the unit in the vicinity of flammable fumes or gasses such as propane tanks or large engines Avoid covering the ventilation openings Always operate th...

Page 6: ...ere is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning...

Page 7: ...lgorithm During normal operation the charger will do a full charge cycle to float stage on Battery Bank 1 Once the float stage is reached the charger starts charging Battery Banks 2 and 3 together wit...

Page 8: ...Battery Bank 3 Chassis Ground The unit chassis has to be grounded properly to the common ground point on the system Digital Remote optional The Display Remote Part Number ACRM1202 sold separately is...

Page 9: ...e battery voltage reaches approximately 13 5V This timer is set to avoid battery overcharging The charger will override the Absorption to Float stage condition and goes to Float stage when it times ou...

Page 10: ...he mounting template on the right to mark the positions of the mounting screws Drill the 4 mounting holes and place the Charger in position and fasten the unit to the mounting surface See mounting loc...

Page 11: ...screws located at the top of the AC compartment cover Remove the top section of the AC Input wire strain relief located at the bottom of the base panel inside the AC wiring compartment by unscrewing t...

Page 12: ...s Remote Port to the COM_2 port on the Remote Display Panel The Remote Display Panel is now ready to use Both charger displays will show CON indicating the chargers are connected in parallel And all...

Page 13: ...display will then show the next menu to continue with other setting parameters NEXT Press the hold the key for longer than 5 seconds to RESET the charger Display will show RST and it will force the ch...

Page 14: ...27 V 0 54V AGM 0 21 V 0 42V For use when Battery Temperature Sensor is in use No setting on the unit is required and the unit will automatically sense the Battery Temperature Sensor when it is connec...

Page 15: ...rent L current in A Charging stages CH1 only Mode 2 Bulk and Absorption stage only Mode 3 Bulk Absorption and Float stage Battery temperature CH1 only Low Lo Normal nor High hi For Lithium battery typ...

Page 16: ...ed channel first and follows with 1 hour of 15 5V equalization process Consult or follow the instruction as provided by the battery manufacturer on how to check the battery electrolyte level and or re...

Page 17: ...g code will display The charger will recover automatically back to the maximum charging current when the environmental temperature drops to below 45 C Over Temperature Shutdown When the charger senses...

Page 18: ...alled The unit will shut down The unit will automatically recover when the battery temperature has reduced to 60 C 140 F For Lithium battery type setting High battery temperature 60 C 140 F is sensed...

Page 19: ...ith back lighting Charging status Battery Voltage Warning and Fault Code A01 E01 09 AC Input and DC Output Connection AC Input Connection Hardwire or AC with EU UK AZ plug DC Output Connection POS Hea...

Page 20: ...ive if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to the manufacturer...

Page 21: ...Page 21...

Page 22: ...Page 22...

Page 23: ...Page 23...

Page 24: ...Page 24...

Page 25: ...Page 25...

Page 26: ...Page 26 Appendix B...

Reviews: