Kisae Abso Charger 12V 100A Owner'S Manual Download Page 3

 

 

Page 

 

 

 

For safe and optimum performance, the 

KISAE Abso Charger

 must be used properly. Carefully read and 

follow all instructions and guidelines in this manual and give special attention to the 

CAUTION

 and 

WARNING

 

statements. 

 

 

PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE 

 

 

Disclaimer 

While every precaution has been taken to ensure the accuracy of the contents of this guide, 

KISAE 

Technology 

assumes no responsibility for errors or omissions. Note as well that specifications and 

product functionality may change without notice. 
 

Important  

Please be sure to read and save the entire manual before using your 

KISAE Abso Charger. 

Misuse 

may result in damage to the unit and/or cause harm or serious injury.  
 

 
 

 

Product Numbers 

AC12100 

Abso Charger 12V 100A 

AC2450

 

Abso Charger 24V 50A 

 

 

Document Part Number 

 

MU AC12100 Rev A

 

 
Service Contact Information 

Email: [email protected] 
Phone : 1 877 897-5778 
Web 

www.kisaepower.com

  

 

 

 

WARNING: 

This product can expose you to chemicals, including Di (2-ethylhexyl) phthalate (DEHP)

 

which is 

known to the State of California to cause cancer, birth defects or other reproductive

 

harm. For more information, 

go to www.p65warnings.ca.gov

 

ADVERTENCIA 

Este producto puede exponerlo a productos químicos, incluidos Di (2-etilhexil) ftalato (DEHP)

 

que el estado de California sabe que causa cáncer, defectos de nacimiento u otros daños

 

reproductivos. Para 

obtener más información, vaya a www.p65warnings.ca.gov

 

 

Summary of Contents for Abso Charger 12V 100A

Page 1: ...Abso Charger 12V 100A AC12100 24V 50A AC2450 Owner s Manual...

Page 2: ...Page 2...

Page 3: ...Abso Charger Misuse may result in damage to the unit and or cause harm or serious injury Product Numbers AC12100 Abso Charger 12V 100A AC2450 Abso Charger 24V 50A Document Part Number MU AC12100 Rev...

Page 4: ...STALLING THE CHARGER 10 5 UNIT OPERATION 13 6 SPECIFICATIONS 19 7 WARRANTY 20 Appendix A1 GEL Flooded AGM Setting CH1 CH2 CH3 Appendix A2 1 Lithium Setting CH1 Appendix A2 2 Lithium Setting CH2 3 Appe...

Page 5: ...an explosion WARNING Explosion hazard Do not use the unit in the vicinity of flammable fumes or gasses such as propane tanks or large engines Avoid covering the ventilation openings Always operate th...

Page 6: ...ere is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning...

Page 7: ...lgorithm During normal operation the charger will do a full charge cycle to float stage on Battery Bank 1 Once the float stage is reached the charger starts charging Battery Banks 2 and 3 together wit...

Page 8: ...Battery Bank 3 Chassis Ground The unit chassis has to be grounded properly to the common ground point on the system Digital Remote optional The Display Remote Part Number ACRM1202 sold separately is...

Page 9: ...e battery voltage reaches approximately 13 5V This timer is set to avoid battery overcharging The charger will override the Absorption to Float stage condition and goes to Float stage when it times ou...

Page 10: ...he mounting template on the right to mark the positions of the mounting screws Drill the 4 mounting holes and place the Charger in position and fasten the unit to the mounting surface See mounting loc...

Page 11: ...screws located at the top of the AC compartment cover Remove the top section of the AC Input wire strain relief located at the bottom of the base panel inside the AC wiring compartment by unscrewing t...

Page 12: ...s Remote Port to the COM_2 port on the Remote Display Panel The Remote Display Panel is now ready to use Both charger displays will show CON indicating the chargers are connected in parallel And all...

Page 13: ...display will then show the next menu to continue with other setting parameters NEXT Press the hold the key for longer than 5 seconds to RESET the charger Display will show RST and it will force the ch...

Page 14: ...27 V 0 54V AGM 0 21 V 0 42V For use when Battery Temperature Sensor is in use No setting on the unit is required and the unit will automatically sense the Battery Temperature Sensor when it is connec...

Page 15: ...rent L current in A Charging stages CH1 only Mode 2 Bulk and Absorption stage only Mode 3 Bulk Absorption and Float stage Battery temperature CH1 only Low Lo Normal nor High hi For Lithium battery typ...

Page 16: ...ed channel first and follows with 1 hour of 15 5V equalization process Consult or follow the instruction as provided by the battery manufacturer on how to check the battery electrolyte level and or re...

Page 17: ...g code will display The charger will recover automatically back to the maximum charging current when the environmental temperature drops to below 45 C Over Temperature Shutdown When the charger senses...

Page 18: ...alled The unit will shut down The unit will automatically recover when the battery temperature has reduced to 60 C 140 F For Lithium battery type setting High battery temperature 60 C 140 F is sensed...

Page 19: ...ith back lighting Charging status Battery Voltage Warning and Fault Code A01 E01 09 AC Input and DC Output Connection AC Input Connection Hardwire or AC with EU UK AZ plug DC Output Connection POS Hea...

Page 20: ...ive if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to the manufacturer...

Page 21: ...Page 21...

Page 22: ...Page 22...

Page 23: ...Page 23...

Page 24: ...Page 24...

Page 25: ...Page 25...

Page 26: ...Page 26 Appendix B...

Reviews: