© MMXIX Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 190625006
SF350-15
SuperFlow® 350 Regulator
Reassembly of the SuperFlow® 350 Demand Regulator
Special note on whisker clamps: There is no left or
right whisker clamp. Both clamps are identical.
If the clamps are not oriented correctly, it will be very
difficult to tighten the screws that secure them. There
is also a good possibility that the clamp will come
off of the whisker, reducing the effectiveness of the
exhaust system in keeping the breathing system dry.
B
WARNING
If the whisker clamps are not installed
properly, the exhaust valves will leak.
This leads to a chance of backflow
into the regulator through the exhaust
valve. In contaminated water diving,
this is a serious emergency.
Whisker Assembly Details
This Screw Head Is Down
Whisker Clamp
Step Facing Towards Regulator
Nut
Nut
This Screw Head Is Up