SF350-14
© MMXIX Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 190625006
Reassembly of the SuperFlow® 350 Demand Regulator
SuperFlow® 350 Regulator
The screws that hold the flange on the
regulator body should be tightened, see "Torque
Specs" on page APNDX-19 for correct torque.
If the flange is tightened too much, the gasket
will protrude into the exhaust valve opening and
interfere with proper regulator performance.
2) Trim off any excess material from the gasket
that might interfere with the operation of the ex-
haust valve.
3) Install the new exhaust valve into the regu-
lator and trim off any excess stem that may in-
terfere with the movement of the lever or inlet
valve.
The exhaust valve is installed on
the outside of the flange.
The stem of the exhaust valve that sticks into
the regulator body must be trimmed.
4) While using the castle wrench to hold the inlet
valve, insert the valve into the bent tube end of
the regulator body. Place the washer sharp side
down, then the spacer over the end of the inlet
valve stem. As an alternate procedure, the wash-
er and spacer may be placed in the recess in the
inside of the regulator body before inserting the
inlet valve stem.