9
-6
EX35(C)/EX40(C)/EX45(C)/EX50(C)
COUNTERMEASURES
CAUSE
6. Electric system is
faulty
7. Heater/air conditioner
motor is faulty
Check the battery and alternator.
The horn switch is faulty. Replace it.
The wiring is faulty. Repair it.
The horn is damaged. Repair or replace it.
The bulb is blown. Replace it.
The blinking device is faulty. Repair or replace it.
The ground and terminal wirings are poorly contacted.
Check and clean them.
The bulb is blown. Replace it.
The ground and terminal wirings are poorly contacted.
Check and clean them.
The fan speed control switch and motor are faulty. Repair or
replace them.
The air suction filter is clogged.
The wiring is short circuited. Check and repair it.
Replace the fan speed control switch.
The motor is faulty. Repair or replace it.
Battery cannot be charged
Horn does not sound
Turn signal lamps do not blink
Work lamps do not come on
Fan speed is slow or no air is
blown out
Fan speed cannot be controlled