Installation and initial operation
32
01.04.2020
Female
PIN
Function
1
Shield
2
Power Supply 9 to 36 V (do not connect)
3
GND
4
CAN1_H
5
CAN1_L
The manufacturers of the excavator control systems take the supply for the
devices directly from the battery. For this reason, pin 2 should not be connected
as this would result in unnecessary current draw when the ignition is switched
off.
In most cases Leica does not use the CAN Open assignment of the M12 plug, but
rather, as follows:
CAN bus Leica iCON3D machine control system
Allocation of 5-pole CAN M12 plug connection, standard cable from Leica
Geosystems AG:
CAN bus, white and black twisted pair
PIN
Colour
Function
1
Brown
+24 V @ 0.75 mm²
2
White
CAN high @ 0.34 mm²
3
Blue
-24 V (Ground) @ 0.75 mm²
4
Black
CAN low @ 0.34 mm²
5*
Grey
Depending on the application @ 0.34 mm²
*With the sensors, the pin is not assigned and not connected:
•
Excavator: XJB-16 Junction box
•
Dozer, Grader: Junction box SLEEP
Receptacle (standard), CAN M12 5-pole, female
Plug, CAN M12 5-pole, male