21
3.
Technical Information
3.1.
Requirements of the carrier machine
NOTICE
To operate the
hydraulic breaker
, the
1 hydraulic circuit
must be available
on the carrier machine.
NOTICE
When
assembling
the hydraulic connections, make sure that the return line is
always connected
first
.
When
dismantling
, always disconnect it
last
.
In order to operate the attachment correctly, set the values for the
operating
pressure
and
oil flow
on the carrier machine.
The setting values are also described on the
type plate
.
NOTICE
A higher operating pressure on the carrier is not permitted and must be
reduced.
3.2.
Operating pressure and oil flow
Type
Oil flow
Operating
pressure
Back pressure
Hydraulic connection
Pressure and tank line
[l/min]
[MPa/bar]
[MPa/bar]
[inch]
SB70
13 - 20
10 / 100
2.5 / 25
G1/2"
SB100
15 - 30
11 / 110
G1/2"
SB150
18 - 40
11 / 110
G1/2"
SB200
25 - 55
13 / 130
G3/4"
SB250
30 - 60
14 / 140
G3/4"
SB300
50 - 70
16 / 160
G3/4"
SB400
75 - 90
15 / 150
G3/4"
SB500
85 - 110
15 / 150
G3/4"
Requirements for