05
In high wind load areas e.g. at excessive heights or very exposed areas when the force
acting upon the solar panel is greater than 2.5kN/m
2
, an additional vertical support rail
KSK0229 - 400 Single Rail Sloping Roof Kit (Extra Wind Loading) may be obtained. Please
refer to the wind loading table – page 29.
On the sloping roof kit, a distance of 1400mm (minimum) and 1700mm (maximum) should
be observed between the top of the lower brackets and the top of the upper brackets.
KSK0217 - 400 Sloping Roof Kit
1. Slide back tile and attach lower
brackets to roof rafter
5. Locate manifold on side rails and
secure with upper clamp bolts
2. Secure side rails to lower bracket with
the pre-drilled holes to the bottom
1400-
1700mm
600-
1100mm (2
0)
800-
1400mm (3
0)
6. Locate horizontal support
rails on the side rails
3. Attach upper brackets to roof rafters
4. Secure side rails to upper
brackets with sliding bolt fixing
'(7$,/%