Universal Firebox
The ZVFCV39, ZVFCV42, and ZVFCV47 are approved as Zero Clearance Universal Fireboxes.
When installing another manufacturer’s log and burner system, follow the manufacturer’s assembly
instructions.
For Framing, refer to appropriate
Framing Specifications
section in this manual.
Follow all
Clearances to Combustibles
in this manual.
When using the optional blower kit (Z46FK) the Thermodisc can be discarded. The two leads from the
blower must be attached directly to the variable speed switch. See
Fan Installation
section for wiring.
Model
Firebox Height
Firebox Width Front
Firebox Width Back
Firebox Depth
Firebox Max BTU
ZVFCV39
26
”
29.75”
22.5”
15.5”
40,000
ZVFCV42
29.125
”
33.875”
26.375
”
15.5”
40,000
ZVFCV47
34.125
”
39.75”
29.75
”
17.25”
40,000
The fireplace hood is packaged on top of the firebox from the factory. It must be installed on the firebox
before operation of the appliance.
The firebox hood must not be modified or replaced with a hood which may be provided with the decorative
type unvented room heater.
USE ONLY KINGSMAN DECORATIVE COMPONENT AND REPLACEMENT PARTS.
Hood
Pull Screen
Pull Screen
Access Cover
8