Installing Burner Systems
Installing Burner Systems into Firebox
The Zero Clearance Fireplaces ZVFCV36 / 42 / 47 have the option of being installed with either the GLVF24
Vent Free Burner Systems or other approved vent free burner systems.
Warning:
Failure to position parts in accordance with these diagrams or failure to use only part specifically
approved with this heater may result in property damages or personal injury.
Installing GLVF24 Vent Free Burner System with grate:
1. If using optional blower it is recommended to install fan now to make installation easier. Refer to
Installation of Optional Fan
section.
2. Follow instructions included with GLVF24 Burner System with grate.
3. Connect gas supply to the burner system. Refer to
Installing Gas Line
section.
4. Proceed to
Log Placement
.
If using another manufacturer’s burner system and logs,
follow manufacturer’s installation instructions.
⚠
WARNING
⚠
WARNING
Failure to keep primary air openings clear,
may result in sooting and property damage.
Turn off heater and allow to cool before cleaning. Only a
qualified service technician should service and repair
appliance.
Cleaning and Servicing of Burner / ODS Pilot
It is recommended to annually inspect and
clean the unit to prevent malfunction and / or
sooting. This operation should be performed by
your dealer or a qualified technician.
Remove log set, handling carefully by holding
gently at each end. (Refer to Log Placement)
Gloves are recommended to prevent skin irritation
from ceramic.
Annual Cleaning / Inspection
• Do not use cleaning fluids to clean logs or any
part of the heater.
• Use a soft bristle brush or a vacuum with brush
attachment.
• Vacuum loose particles and dust from burner
ports, valve and blower compartments.
• Vacuum any accumulation of lint from primary
mixing tube.
• Inspect ODS pilot for operation, accumulation of
lint at the air inlet holes.
• Verify flame pattern and log placement for proper
operation.
• Verify that all ports ignite and cross over smoothly
from rear to front burner.
⚠
CAUTION
Never use a wire, needle, or similar object
to clean ODS / Pilot. This can damage
ODS / Pilot.
Air Inlet Holes
Flame should touch thermocouple and thermopile
35