background image

BASIC ONE YEAR WARRANTY

During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials 
or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate
schedule and any repair work must be done through an authorized Kingsman dealer.

LIMITED LIFETIME WARRANTY

The heat exchanger, combustion chamber and burner of every Kingsman product excluding the Outdoor Firepit are warranted against 
materials or workmanship during the period the product is owned by the original owner. The part to be replaced must be returned to our 
distributor in exchange for the replacement part. Any labor, material, freight and/or handling charges associated with any repair 
or replacement pursuant to this Limited Lifetime Warranty will not be covered by this warranty.

GENERAL TERMS

In lieu of providing a replacement part, we may, at our option, provide the distributor's component purchase price from us or a credit equal 
to the distributors component purchase price from us toward the purchase of any new unit which we distribute. If a credit is given 
in lieu of a replacement part, the rating plate from the unit being replaced must be submitted on a warranty claim, and the unit being
replaced must be made available to our distributor for disposition.

In establishing the date of installation for any purpose, including determination of the starting date for the term of this Limited Lifetime
Warranty, reasonable proof of the original installation date must be presented*, otherwise the effective date will be based upon the date of
manufacture plus thirty (30) days.

We will not be responsible for and you, the user, will pay for: (a) damages caused by accident, abuse, negligence, misuse, riot, fire, flood,
or Acts of God (b) damages caused by operating the unit where there is a corrosive atmosphere containing chlorine, fluorine, or any other 
damaging chemicals (other than in a normal residential environment) (c) damages caused by any unauthorized alteration or repair 
of the unit affecting its stability or performance (d) damages caused by improper matching or application of the unit or the unit's components
(e) damages caused by failing to provide proper maintenance and service to the unit (f) any expenses incurred for erecting, disconnecting 
or dismantling the unit (g) parts or supplies used in connection with service or maintenance (h) damage repairs, inoperation or inefficiency
resulting from faulty installation or application (i) electricity or fuel costs or any increase in electricity or fuel cost whatsoever including 
additional or unusual use of supplemental electric heat.

We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure of this unit. 
We have not made and do not make any representation or warranty of fitness for a particular use or purpose, and there is no implied condition
of fitness for a particular use or purpose. We make no express warranties except as stated in this Limited Lifetime Warranty. No one is authorized
to change this Limited Lifetime Warranty or to create for us any other obligation or liability in connections with this unit. Any implied 
warranties shall last for one year after the original installation. Some states and provinces do not allow the exclusion or limitation of incidental 
or consequential damages or do not allow limitations on how long an implied warranty or condition lasts, so the above limitations or exclu-
sions may not apply to you. The provisions of this limited warranty are in additions to and not a modification of or subtraction from any statu-
tory warranties and other rights and remedies provided by law.

Save this certificate. It gives you specific legal rights, and you may also have other rights which may vary from state to state and province to province.

In the event your unit needs servicing, contact your dealer or contractor who installed or serviced your unit. When requesting service, 
please have the model and serial number from each unit readily available. If your dealer needs assistance, the distributor is available for support
and we, in turn support the distributor's efforts.

Fill in the installation date and model and serial numbers of the unit in the space provided below and retain this limited warranty for your files.

Model No.

Serial No.

Date installed

Dealer or Contractor Name :

*To receive advantage of your warranty, you must retain the original records that can establish the installation date of your unit.

LIMITED LIFETIME WARRANTY

This Limited Lifetime Warranty applies only while the unit remains at the site of the original
installation and only if the unit is installed inside the continental United States, Alaska, Hawaii,
and Canada. The warranty applies only if the unit is installed and operated in accordance 
with the printed instructions and in compliance with applicable installation and building codes 
and good trade practices.

The Ultimate in Design, Engineering & Quality

Summary of Contents for ZV3600

Page 1: ...tion adjustment alteration service or maintenance can cause property damage personal injury or loss of life Refer to this manual Installation and service must be performed by a qualified installer ser...

Page 2: ...wn between each Be aware during log and firebox paint curing that a white deposit may be developing on the inside of the glass doors It is important to remove this white deposit from the glass doors w...

Page 3: ...rating and maintenance instructions 11 General glass information 12 Confirming proper venting of appliance 12 Log assembly and fan kit 13 Log Placement 14 20 Millivolt system lighting burner control 2...

Page 4: ...other flammable material should not be placed on or near the appliance This appliance should not be used as a drying rack for clothing nor should Christmas stockings or decorations be hung from it 16...

Page 5: ...pliance or equipment such that only one service switch services both the appliance and the carbon monoxide detector Have battery back up power Meet ANSI UL 2034 Standards and comply with NFPA 720 2005...

Page 6: ...rame in accordance with the fireplace dimensions specified See framing diagrams Bend nailing tabs forward on left and right of unit and place fireplace into framed enclosure This allows for 1 2 in fro...

Page 7: ...7 Framing for your Gas Fireplace cont FRAMING FOR ZV3600 FRAMING FOR ZV4200 4 B Vent 4 B Vent...

Page 8: ...sed appearance For COMBUSTIBLE materials extending in front of fireplace consult Mantel and Mantel Leg Drawings If wide brass surround is used finish materials must be flush with front of unit Note Wh...

Page 9: ...iting the fan housing into the thermodisk Electrical Services All optional fan kits are equipped with a 120V 60 Hz blower Note All electrical connections are to be made in accordance with CSA Standard...

Page 10: ...Place rear brick panel up against the back of the firebox 2 Loosen screw holding brick clip in position swing clip up out of the way and place side brick up to rear brick and flush against side wall...

Page 11: ...Natural Gas 0 4500 ft 44 Airshutter 1 16 Propane Gas 0 4500 ft 54 Airshutter 3 16 Important Always check for gas leaks with a soap and water solution Do not use open flame for leak testing Operating...

Page 12: ...ted behind upper grill or unfasten latches if so equipped 2 To remove pull frame forward and lift from bottom door retain er channel Confirming Proper Venting of Appliance To check for proper drafting...

Page 13: ...ined between glowing ember and underside of front log ember bed area 10 Front log should be centered on the log supports between the front and rear burners Pull log against the front of the sup ports...

Page 14: ...the front burner to the surface of the ember plates and over crossover to the same height as ember plates Height on front burner 1 2 to 3 4 Height on ember plates 3 4 to 1 Do not cover back air openi...

Page 15: ...charred area sits between front and rear log Step 10 Make sure that a space of at least 3 4 is maintained between glowing ember and underside of front log ember bed area Step 11 Place decorative moon...

Page 16: ...that the ember plates 2 pces are between front and back burner Step 4 Break glowing embers into thumbnail size Place glowing embers on to the surface of the front burner to the surface of the ember p...

Page 17: ...Step 7 Place right crossover log across front and back logs using the log placement pin as a guide Step 8 Place left crossover log across front and back logs using the log placement pin as a guide Ste...

Page 18: ...rear log over rear log holder and lower into position Be sure that the log does not sit on rear burner but behind and lower than burner Step 2 Locate flat surface on Log 2 and place directly onto left...

Page 19: ...Ember material from plastic bag tear off dime and nickel sized pieces and place directly onto front burner tube and crossover tube NOTE Do not place embers onto rear burner tube Step 5 Position Log 4...

Page 20: ...of Log 5 Step 8 Slide Log 7 between Log 1 and Log 2 Step 9 Position Log 8 up against the 3rd grate post from the right and position upper section of Log 8 against Logs 2 and 7 Step 10 Place crushed r...

Page 21: ...pilot screw to provide proper sized flame Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire Size Max Length 14 GA 100 FT 16 GA 64 FT 18 GA 40 FT 20 GA 25 FT 22 GA 1...

Page 22: ...22 SPILL SAFETY SWITCH Wiring Diagram 820 639 and 820 640 True Millivolt Systems This System does not have a thermocouple For Units with serial numbers greater than 36350 For SIT 820633 820634 Valves...

Page 23: ...y be used to adapt existing chimney or liner to fireplace Single wall pipe must have 6 clearance to combustibles Chimney Installations Three types of chimney systems may be used with this unit A chimn...

Page 24: ...r Straight Series 1 Z36DDTS1P Trim Polish for Designer Straight Series 1 24 Parts List PART NO DESCRIPTION Child Safety Screens Z36CSS Child Safety Screen 36 DV Fireplaces ZV4200N Fireplace Decorative...

Page 25: ...above 1000 P136WR Thermopile GOAI 524 1001 P069SI Electrode Sparker 915 069 TC SIT 1001 P165SI Orifice Pilot NG 977 165 TC SIT 1001 P167SI Orifice Pilot LP 977 167 TC SIT 1001 P639SI Valve Nova LP Hi...

Page 26: ...urn valve knob on On place wall switch on On Millivolt meter should read greater than 100mV If the reading is okay and the burner does not come on replace the gas valve Pilot burning no gas to burner...

Page 27: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...