23
Vent Instructions
NOTE: A chimney venting this fireplace shall not vent any
other appliance.
This appliance may be vented into various types of applications:
“A” Vent of solid fuel wood burning chimney, Masonry Clay lining
and “B” Vent liquid fuel gas chimney.
NOTE: Four (4) inch is required if existing chimney is five (5)
inches or larger. Four (4) inch single wall or “B” Vent liquid
fuel gas chimney may be used to adapt existing chimney or
liner to fireplace.
Single wall pipe must have 6” clearance to combustibles
Chimney Installations
Three types of chimney systems may be used with this unit.
A chimney venting this fireplace shall not vent any solid fuel burning appliance.
When installing with “B” Vent liquid fuel gas chimney install as per
“B” Vent Manufacturer Installation specifications. Offset vertical or
vertical installations may be installed.
NOTE: Installation of “B” Vent must follow “B” Vent
Manufactures s Installation instructions when being used.
Seal all connections in venting system.