1000 - 302

Arch Door Frame

1000 - 305

Glass - Robax or coated Neoceram

1000 - 306

Gasket - Door

1000 - EMBER

Ember Kit

1000 - 700

Log Set (4 Pieces)

1000 - 085

Variable Speed Wall Mount Switch

2000 - 080

Sensor for Auto On/Off Fan Kit

Kingsman Fireplace Part Numbers

and Specifications Options

Product

Description

Number

ZDV1160

Zero Clearance Fireplace (natural gas) Top Vent, 
Arch Door

ZDV2560

Zero Clearance Fireplace PROPANE Top Vent, 
Arch Door

ZDV360

Zero Clearance Fireplace (natural gas) Back Vent, 
Straight Door

ZDV960

Zero Clearance Fireplace (natural gas) Back Vent, 
Arch Door

ZDV1560

Zero Clearance Fireplace (natural gas) Top Vent, 
Straight Door

ZDV1960

Zero Clearance Fireplace PROPANE Top Vent, 
Straight Door

Kingsman Fireplace Accessories

Catalog 
Number

Description

ZIFK

Fan Kit (Thermostatic On/Off)

ZIRL

Refractory Kit

ZIRC

Cordless Remote Control

ZIMT

Thermostat Wall Mount Millivolt

Kingsman Fireplace Options

Catalog 
Number

Description

Grills

ZIGBL

Grills - Black

ZIGAB

Grills - Antique Brass

ZIGPB

Grills - Polish Brass

ZIGAL

Grills - Almond

ZIGBG

Grills - Burgundy

ZIGGR

Grills - Green

Surround Kits

ZISAB

Surround - Antique Brass

ZISPB

Surround - Polish Brass

ZISAL

Surround - Almond

ZISBG

Surround - Burgundy

ZISGR

Surround - Green

ZISSAB

Surround (Slim Line) - Antique Brass

ZISSPB

Surround (Slim Line) - Polish Brass

Arch Door Frame

ZIADAB

Arch Door Frame - Antique Brass

ZIADPB

Arch Door Frame - Polish Brass

ZIADAL

Arch Door Frame - Almond

ZIADBG

Arch Door Frame - Burgundy

ZIADGR

Arch Door Frame - Green

Kingsman Fireplace Venting

Catalog 
Number

Description

ZDVHSK

Horizontal Vent Starter Kit - (Back Vent)
Starter Kit Contains:
Horizontal Vent Termination, Wall Thimble, 4”-7”
Dia. x 36” Flex Pipe
Clamps, Silicone.

FDVVT15

Vertical Vent Termination (8’ to 15’)

FDVVT30

Vertical Vent Termination (15’ to 30’)

FDVHT

Horizontal Vent Termination

ZDVAIS

Attic Insulation Shield

ZDVVOS

Offset Support

ZDVFS

Firestop Spacer

ZDVRS

Roof Support

ZDVSS

Siding Shield

ZDVWT

Wall Thimble (Horizontal Venting)

ZDVAAF

Flashing 0/12 - 6/12

ZDVAF2

Flashing 6/12 - 9/12

ZDVAF3

Flashing 9/12 - 12/12

ZDVFK4

Flex Kit (4” & 7” Dia.) x 2’ (Unexpanded) 4’ Expanded

ZDVFK8

Flex Kit (4” & 7” Dia.) x 4’ (Unexpanded) 8’ Expanded

ZDVFK20

Flex Kit (4” & 7” Dia.) x 10’ (Unexpanded) 20’ Expanded
*Kits are complete with spring stand-offs, clamps, silicone.

ZDV4FC

Flex Connector 4” Diameter

ZDV7FC

Flex Connector 7” Diameter

ZDV4FCL

Flex Clamp 4”

ZDV7FCL

Flex Clamp 7”

Summary of Contents for "Zero Clearance" ZDV1001

Page 1: ...nce What To Do If You Smell Gas Do not try to light any appliance Extinguish any open flame Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier...

Page 2: ...8 Vent termination 9 10 Venting graph 10 General vent installation information 11 Installation of top flue side wall venting 11 12 Installation of back vents 13 Repair parts list 13 Valve System Part...

Page 3: ...vice person A professional service person should be called to inspect this appliance annually Make it a practice to have all your gas appliances checked annually 6 Control compartments burners and air...

Page 4: ...llation recommendation when installing this fire place against non insulated exterior wall or chase it is recommend ed that the outer walls be insulated to conform to applicable insula tion codes Dryw...

Page 5: ...pressure testing of the gas supply piping sys tem at test pressures equal to or less than 1 2 PSIG 3 5 KPa Note The gas line connection may be made of 1 2 rigid pipe 1 2 copper pipe or an approved fl...

Page 6: ...should any solid fuels wood paper card board coal be used in this appliance Note It is normal for your gas fireplace to give off some odor the first time it is burned This is due to the curing of the...

Page 7: ...plug on the inside wall of the access area opposite the fan Large holes are provided to allow wiring to enter the access area on the left of the unit Connect the power sensor and variable speed wall...

Page 8: ...that turns the main burner on or off If main burner does not light immediately when you turn the gas control valve to ON ensure that the wall switch is in the ON position NOTE The On Off wall switch...

Page 9: ...driveway located on public property 7 feet 2 1m minimum 3 V NOTE Clearances are to the terminal center line Add 6 inches to clearances not indicated as measured from center line NOTE Local Codes or R...

Page 10: ...s are required the horizontal run length must be reduced to 7 feet How To Use The Vent Table 1 Determine the height of the system and the number of bends required 2 Having determined the vertical dist...

Page 11: ...ing on the wall Cut a hole through the exterior wall allowing for a 11 x 11 minimum inside framing or an 8 1 2 diameter hole if venting through a non combustible wall Center wall thimble over 11 x 11...

Page 12: ...NOTE At the top edge of the flashing plate lift the shingles and nail the plate to the roof deck then cement the shingles to the plate with a suitable waterproof mastic Ensure that the chimney is plum...

Page 13: ...d must be cut to comply Install wall thimble Place fireplace into place and secure to floor with nailing tabs Step 5 Mount vent termination make sure 4 and 7 pipes are siliconed Caulk around wall thim...

Page 14: ...urround Kits ZISAB Surround Antique Brass ZISPB Surround Polish Brass ZISAL Surround Almond ZISBG Surround Burgundy ZISGR Surround Green ZISSAB Surround Slim Line Antique Brass ZISSPB Surround Slim Li...

Page 15: ...h ON wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Generator may not be generating Check generator with millivolt meter...

Page 16: ...ing its stability or performance d damages caused by improper matching or application of the unit or the unit s components e damages caused by failing to provide proper maintenance and service to the...

Reviews: