Millivolt System, Lighting, & Burner Control

Lighting Instructions

1. Open access grill on bottom.

2. Push in gas control knob slightly and turn clockwise to “OFF”.

NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is
pushed in slightly. Do not force.

3. Wait five (5) minutes to clear out any gas remaining in burner com-

bustion chamber.

4. Turn knob on gas control counter-blockwise to “PILOT”.

5. Push in control knob all the way and hold in. Immediately light the

pilot with piezo-electric ignitor while continuing to push knob in for
one (1) minute. Release knob. Pilot should remain lit. If it goes out,
repeat steps 2 through 5 until pilot remains lit.

– If knob does not pop up when released, stop and immediately call

your service technician or gas supplier.

– If pilot will not stay lit after several tries, turn the gas control

knob to “OFF” and call your service technician or gas supplier.

6. Turn gas control knob counter-clockwise to “ON”.

7. All models are supplied with a wall switch that

turns the main burner on or off. If main burner does
not light immediately when you turn the gas control
valve to “ON” ensure that the wall switch is in the
“ON” position.

NOTE: The “On/Off” wall switch may be replaced
with a wall thermostat allowing main burner to
light and turn off automatically depending upon
thermostat setting and room temperature.

8. Adjust the gas flow (flame height) with the

HI/LOW gas control knob on valve.

NOTE: Standard gas control valve without
HI/LOW is designed to be either fully on or fully
off. It should never be used to vary flame height or
adjust gas flow.

– LP valve is non-adjustable.

– NG valve is adjustable with HI/LOW control
knob.

9. Close control access grill.

Pilot Burner
Adjustment

1. Remove pilot adjust-

ment cap.

2. Adjust pilot screw to

provide proper sized
flame.

3. Replace pilot adjust-

ment cap.

4. Leak Test.

To Turn Off Gas Appliance

Turn off all electric power to the appliance if service is to be per-
formed. Open control access grill.

Push in gas control knob  slightly and turn clockwise to “OFF”. Do not
force. Close control access grill.

Caution: Do Not Wire 120 Volt Power To Millivolt Switches Or Thermostats.

THERMOCOUPLE
OR GENERATOR

Summary of Contents for "Zero Clearance" ZDV1001

Page 1: ...nce What To Do If You Smell Gas Do not try to light any appliance Extinguish any open flame Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier...

Page 2: ...8 Vent termination 9 10 Venting graph 10 General vent installation information 11 Installation of top flue side wall venting 11 12 Installation of back vents 13 Repair parts list 13 Valve System Part...

Page 3: ...vice person A professional service person should be called to inspect this appliance annually Make it a practice to have all your gas appliances checked annually 6 Control compartments burners and air...

Page 4: ...llation recommendation when installing this fire place against non insulated exterior wall or chase it is recommend ed that the outer walls be insulated to conform to applicable insula tion codes Dryw...

Page 5: ...pressure testing of the gas supply piping sys tem at test pressures equal to or less than 1 2 PSIG 3 5 KPa Note The gas line connection may be made of 1 2 rigid pipe 1 2 copper pipe or an approved fl...

Page 6: ...should any solid fuels wood paper card board coal be used in this appliance Note It is normal for your gas fireplace to give off some odor the first time it is burned This is due to the curing of the...

Page 7: ...plug on the inside wall of the access area opposite the fan Large holes are provided to allow wiring to enter the access area on the left of the unit Connect the power sensor and variable speed wall...

Page 8: ...that turns the main burner on or off If main burner does not light immediately when you turn the gas control valve to ON ensure that the wall switch is in the ON position NOTE The On Off wall switch...

Page 9: ...driveway located on public property 7 feet 2 1m minimum 3 V NOTE Clearances are to the terminal center line Add 6 inches to clearances not indicated as measured from center line NOTE Local Codes or R...

Page 10: ...s are required the horizontal run length must be reduced to 7 feet How To Use The Vent Table 1 Determine the height of the system and the number of bends required 2 Having determined the vertical dist...

Page 11: ...ing on the wall Cut a hole through the exterior wall allowing for a 11 x 11 minimum inside framing or an 8 1 2 diameter hole if venting through a non combustible wall Center wall thimble over 11 x 11...

Page 12: ...NOTE At the top edge of the flashing plate lift the shingles and nail the plate to the roof deck then cement the shingles to the plate with a suitable waterproof mastic Ensure that the chimney is plum...

Page 13: ...d must be cut to comply Install wall thimble Place fireplace into place and secure to floor with nailing tabs Step 5 Mount vent termination make sure 4 and 7 pipes are siliconed Caulk around wall thim...

Page 14: ...urround Kits ZISAB Surround Antique Brass ZISPB Surround Polish Brass ZISAL Surround Almond ZISBG Surround Burgundy ZISGR Surround Green ZISSAB Surround Slim Line Antique Brass ZISSPB Surround Slim Li...

Page 15: ...h ON wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Generator may not be generating Check generator with millivolt meter...

Page 16: ...ing its stability or performance d damages caused by improper matching or application of the unit or the unit s components e damages caused by failing to provide proper maintenance and service to the...

Reviews: