Optional LED Lighting –
Custom Enclosures
NOTE
: If appliance is directly connected to an electrical supply, it must be anchored using anchor points provided in
bottom of appliance. Use cord and wire restraints provided also.
Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian
National Electrical Code in Canada.
⚠
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three prong (grounding)
plug for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from
this.
The fireplace receptacle must be connected to an
external GFI protected outlet installed near the fireplace.
Before Servicing
1. Ensure all power supply is shut off.
2. Label all wires prior to disconnecting when servicing
control. Wiring errors can cause improper and
dangerous operation.
SIDE VIEW
CUSTOM
ENCLOSURE
-Junction Box-
Must be connected to
an external GFI outlet
JUNCTION
BOX
LED
CONTROL
BOX
LED LIGHT
STRIP
LED LIGHT
STRIP