Custom Enclosures-
OB24 / 36 / 48 / 72 / 96
(Must be non-combustible)
Multiple burners can be connected together in series.
ENCLOSURES MUST BE NON-COMBUSTIBLE.
Enclosures
shown are suggestions only. Refer to
Clearance to Combustibles
section of manual.
NOTE
: all manual valve systems are shipped as LP systems (MAP) with accompanying orifice for NG conversion.
All millivolt valve systems are shipped as NG systems (MVN) and require a conversion kit for LP conversion.
NOTE
: For propane installations see
Enclosures for LP (Propane) Gas Supply Systems.
3” MIN
3” MIN
5-3/4”
Required Openings for
Stock Burners
OB24 – 5-3/4” x 24-1/2”
OB36 – 5-3/4” x 36-1/2”
OB48 – 5-3/4” x 48-1/2”
OB72 – 5-3/4” x 72-1/2”
OB96 – 5-3/4” x 96-1/2”
Burners may be connected
together in any combination.
When connecting additional
burners, add desired lengths
(24”, 36”, 48”, 72”, 96”) plus
Required Opening for total
opening (e.g. 24” + 72-1/2” +
24” = 120-1/2”).
NOTE:
Flame height will be
noticeably higher on
OB48
burners. This can be manually
adjusted.
Remove ends when
connecting burners.
END VIEW
ALL BURNERS
Maximum height of
media is 1” above tray.
LED Light Strips
must be
at least 1-5/8” below and
2-5/8” away from Burner
Tray.
LED
Light
Strip
LED
Light
Strip
8” MIN
8” MIN
8” MIN
Burner Tray must
be supported.
REFER TO
Enclosures for LP
(Propane) Gas Supply
Systems
NOTE: All Gas Controls and
connections must be readily
removable, supported, or accessible.
12