Gas Conversion –PART A - MILLIVOLT SYSTEMS -
NOTE: CONVERSION SHOULD BE COMPLETED BEFORE BURNER IS INSTALLED.
Caution- the gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the
conversion.
TO CONVERT MILLIVOLT GAS SYSTEMS:
1. Remove [2] screws from Orifice Retainer Bracket.
2. Remove Burner Orifice from Air Shutter. Using a
1/2” wrench, disconnect Burner Orifice from brass
fitting and replace with appropriate Burner Orifice.
3. Set Air Shutter Adjustment to
Fully Open for LP
,
and
1/16” for NG
.
4. Re-insert new Burner Orifice into Air Shutter.
5. Re-attach Orifice Retainer Bracket to Burner Tray.
6. Remove Filler Strips and Pilot Shield to access Pilot
Assembly.
7. Install new Pilot Orifice and Hi/Lo Valve Regulator by
following instructions supplied with Conversion Kit (also see
Parts B & C of Conversion Kit Instructions).
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the
manufacturer’s instructions and all applicable codes and requirements of the Authority
Having jurisdiction. If the information on in these instructions is not followed exactly, a
fire, explosion or production of carbon monoxide may result causing property damage,
personal injury or loss of life.
The qualified service agency is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of the converted appliance is
checked as specified in the manufacturer’s instructions supplied with the kit.
Pilot Shield
Pilot Assembly
Filler Strip
Burner Orifice
See Chart for Size
Orifice Retainer Bracket
Burner Tray
Filler Strip
TANK RETAINER
Included with all MAP Burners
and LP Conversion Kits
NOT USED ON FIRE TABLES.
Air Shutter Adjustment:
1/16” for Natural Gas
Fully Open for Propane
46