I33CS -Mantel Clearance Shield- For IDV26 / IDV33 / IDV43
(
Must be used with a CV, CV1 or CV3 and a backing Surround.)
The Mantel Clearance Shield will reduce the required height of a Combustible Mantel by the following amounts:
IDV26 - 6-7/8”
IDV33 - 10-5/8”
IDV36 – 10-1/8”
IDV43 – 10-1/8”
See the chart below for required Combustible Mantel height when using the Mantel Clearance Shield.
Mantel Height From Bottom of Unit
(When Using Mantel Clearance Shield)
I26CV & I26S1
I33CV & I33SS1
I36CV & I36SS1
I43CV & I43S4432
A
28-1/2”
26-1/4”
34-1/2”
34-1/2”
B
30-1/2”
28-1/4”
36-1/2”
36-1/2”
C
32-1/2”
30-1/4”
38-1/2”
38-1/2”
D
34-1/2”
32-1/4”
40-1/2”
40-1/2”
E
36-1/2”
34-1/4”
42-1/2”
42-1/2”
F
38-1/2”
36-1/4”
44-1/2”
44-1/2”
Contents of Kit:
[1] Mantel Clearance Shield c/w Screws
WARNING:
Combustible objects
must not be placed on
a non-combustible
mantel unless the non-
combustible mantel
meets the minimum
height and width
requirements for a
combustible mantel.
(See next page for Installation Instructions)
Mantel
Clearance
Shield
Mantel
Clearance
Shield
Surround