Gas Conversion for Modulator
– PART C
68
Page 1: ...2017 ZERO CLEARANCE VENTED GAS FIREPLACE Installation Instructions INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference A Division of R Co Inc 2340 Logan Av...
Page 2: ...d Framing 28 29 MQRB5143 Combustible Enclosure Heights 30 MQRB5143 Surround Dimensions Surround Clearances 31 MQRB5143 Facing Material Requirements 32 MQRB5143 Mantel Clearances Clearance to Combustib...
Page 3: ...1 Basic Manual Hi Lo Manual On Off 82 Configuration 2 Remote ON OFF and Manual HI LO Capabilities 83 Operating the Receiver Without Batteries For GT EGT GTM EGTM Remote Controls 84 Configuration 3 Rem...
Page 4: ...ews Notch in Mount Bracket Insert top of Screen into fireplace opening and push bottom in Drop Screen into place Mount Brackets will lock screen in place To remove Safety Screen WAIT UNTIL FIREPLACE I...
Page 5: ...COOL Locate approximate top center of screen Push upward and inward in a rapid motion Bottom of screen will push out Locate approximate top center of screen Push upward and inward in a rapid motion WA...
Page 6: ...struction contractors and finishers Frame unit with metal studs minimum 20 gauge Wooden studs may be used but may cause drywall screws to pop or pull due to wood studs drying out Minimum of 1 2 CONCRE...
Page 7: ...e sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can...
Page 8: ...due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Make sure that the ga...
Page 9: ...ication plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to be easily read from a distance of eight f...
Page 10: ...r to the indoor gas fireplace being installed A Minimum sheltering cover overhang of 1 2 the distance from the base of the fireplace to the ceiling base of roofline is required EXAMPLE The bottom of t...
Page 11: ...ing Optional Surround Maximum Thickness for Non Combustible Material is 3 4 Qty 2 Nailing Tabs are located on each corner of the fireplace Steel Framing Stud If Combustible Wood Framing Studs are used...
Page 12: ...quired for this unit Certified for installation in a bedroom or bedsitting room In Canada must be installed with listed millivolt thermostat In USA see local codes Stand off Locations Make note of whe...
Page 13: ...Set for a Left Hand Burner System Right Hand Burner System Requires Valve to be relocated to right side of unit MQRB4436 Fireplace Dimensions All Units Can Be Vented Vertically Left Burner System Righ...
Page 14: ...closure Enclosure must be 53 1 2 inside width Opening should be greater than 46 1 2 minimum Insert airbox on side of unit first and swing into place Framing Enclosure Around Fireplace If unit is in pl...
Page 15: ...Surround Maximum Thickness for Non Combustible Material is 3 4 Continued on next page Framing Style shown is for illustration purposes only This structure is NOT load bearing Steel Stud Framing Shown...
Page 16: ...See Nailing Tab Guide and MQRB4436SK MQRB5143SK MQRB6961SK pages before placing unit into the framed opening Steel Stud Framing Shown Steel Framing Stud Steel Framing Stud Steel Framing Studs Steel F...
Page 17: ...ombustible material is 3 4 Continued Framing Style shown is for illustration purposes only This structure is NOT load bearing Steel Stud Framing Shown 17 Min Dimension is for Wall Surface Flush with f...
Page 18: ...4 See Nailing Tab Guide and MQRB4436BK MQRB5143BK MQRB6961BK pages before placing unit into the framed opening Steel Stud Framing Shown Steel Framing Stud Steel Framing Stud Steel Framing Stud Steel F...
Page 19: ...inimum of two feet vertical off the flue before going horizontal Kingsman Flex venting MUST be used on the MQRB4436 Use of DuraVent DirectVent Pro or other hard pipe Venting systems is not permitted 3...
Page 20: ...hick with a 3 4 space behind the frame When using Surrounds Maximum Thickness for Non Combustible Facing Materials is 3 4 The Fireplace may be covered up to within 1 2 of the Fireplace Opening with no...
Page 21: ...same for all Models 4436N 4436NE 4436LP 4436LPE Note If using Optional Surround See Surround Clearances Section Steel Stud Framing Shown Steel Stud Framing Shown Note Do not drive excessively long sc...
Page 22: ...eiling Height from bottom of fireplace 60 153cm Top from Stand offs 0 0cm Top of 90 Bend under 72 Enclosure 5 With Wall Thimble Shield Z57WTS All Vent Systems Top of 90 Bend over 72 Enclosure 4 All Ve...
Page 23: ...72 See MQRB5143 Combustible Enclosure Heights page 5 A Hearth is not required for this unit Certified for installation in a bedroom or bedsitting room In Canada must be installed with listed millivol...
Page 24: ...Burner System Right Hand Burner System Requires Valve to be relocated to right side of unit MQRB5143 Fireplace Dimensions Left Burner System Right Burner System All units can be vented vertically Left...
Page 25: ...closure Enclosure must be 60 1 2 inside width Opening should be greater than 53 1 2 minimum Insert airbox on side of unit first and swing into place Framing Enclosure Around Fireplace If unit is in pl...
Page 26: ...al Surround Maximum Thickness for Non Combustible Material is 3 4 Continued 15 3 8 Framing Style shown is for illustration purposes only This structure is NOT load bearing Steel Stud Framing Shown Air...
Page 27: ...See Nailing Tab Guide and MQRB4436SK MQRB5143SK MQRB6961SK pages before placing unit into the framed opening Steel Stud Framing Shown Steel Framing Stud Steel Framing Stud Steel Framing Studs Steel F...
Page 28: ...ustible material is 3 4 Continued Framing Style shown is for illustration purposes only This structure is NOT load bearing Steel Stud Framing Shown 17 Min Airbox must maintain Min 1 Clearance From Com...
Page 29: ...4 See Nailing Tab Guide and MQRB4436BK MQRB5143BK MQRB6961BK pages before placing unit into the framed opening Steel Stud Framing Shown Steel Framing Stud Steel Framing Stud Steel Framing Stud Steel F...
Page 30: ...ing Shown For Propane Horizontal installations the venting must be a minimum of two feet vertical off the flue before going horizontal 51 1 2 Min Natural Gas 53 7 8 Min for Propane 21 5 8 Min for Natu...
Page 31: ...are 1 thick with a 3 4 space behind the frame When using Surrounds Maximum Thickness for Non Combustible Facing Materials is 3 4 The Fireplace may be covered up to within 1 2 of the opening with non c...
Page 32: ...same for all Models 5143N 5143NE 5143LP 5143LPE Note If using Optional Surround See Surround Clearances Section Steel Stud Framing Shown Steel Stud Framing Shown Note Do not drive excessively long sc...
Page 33: ...e of Unit 1 25cm Minimum Ceiling Height from bottom of fireplace 60 153cm Top from Stand offs 0 0cm Top of 90 Bend under 72 Enclosure 5 With Wall Thimble Shield Z57WTS All Vent Systems Top of 90 Bend...
Page 34: ...ght inches 78 See MQRB6961 Combustible Enclosure Heights page 5 A Hearth is not required for this unit Certified for installation in a bedroom or bedsitting room In Canada must be installed with liste...
Page 35: ...MQRB6961 Locating Your Appliance All units are Factory Set for a Left Hand Burner System Right Hand Burner System Requires Valve to be relocated to right side of unit MQRB6961 Fireplace Dimensions 35...
Page 36: ...closure Enclosure must be 78 1 2 inside width Opening should be greater than 71 1 2 minimum Insert airbox on side of unit first and swing into place Framing Enclosure Around Fireplace If unit is in pl...
Page 37: ...ickness for non combustible material is 3 4 Continued Framed Opening 71 1 2 x 45 1 2 Framing style shown is for illustration purposes only This structure is NOT load bearing Steel Stud Framing Shown F...
Page 38: ...the Nailing Tab Guide and MQRB5143SK MQRB6961SK pages before placing unit into the framed opening Steel Stud Framing Shown 19 3 8 20 3 8 Steel Framing Stud Steel Framing Stud Steel Framing Studs Stee...
Page 39: ...e Add 1 2 to this Dimension where a non combustible wall surface will cover the unit see Nailing Tab Guide page also 21 Min FRAMED OPENING 71 1 2 X 45 1 2 CANTILEVER FINISHED MINIMUM OPENING IS 77 1 2...
Page 40: ...3 4 See the Nailing Tab Guide and MQRB5143BK MQRB6961BK pages before placing unit into the framed opening Steel Stud Framing Shown Steel Framing Stud Steel Framing Stud Steel Framing Stud Steel Frami...
Page 41: ...on Single Side Installation Only Steel Stud Framing Shown Steel Stud Framing Shown MQRB6961 The Wall Thimble Shield Z57WTS is required in All Enclosures below 78 Seventy Eight Inches Place Wall Thimbl...
Page 42: ...hick with a 3 4 space behind the frame When using Surrounds Maximum Thickness for Non Combustible Facing Materials is 3 4 The Fireplace may be covered up to within 1 2 of the Fireplace Opening with no...
Page 43: ...for all Models 6961N 6961NE 6961LP 6961LPE Note If using Optional Surround MQRB6961 See Surround Clearances Section Steel Stud Framing Shown Steel Stud Framing Shown Note Do not drive excessively lon...
Page 44: ...bottom of fireplace 64 Vertical Venting 68 Horizontal Venting See MQRB6961 Combustible Enclosure Heights page Top from Stand offs 0 0cm Top of 90 Bend under 78 Enclosure 6 1 2 With Wall Thimble Shield...
Page 45: ...cing fireplace into framed opening you must install the Firebox Cover and the Heat Shield Assembly onto the back of the unit The remaining parts of this kit can be installed after the fireplace is ins...
Page 46: ...g 1 5 Place the bottom of the door into the door retainer slot and then secure the door with the top latches See Door and Glass page in manual if more information is required 6 To locate Valve Access...
Page 47: ...Fig 1 MQRB4436PLB MQRB5143PLB or MQRB6961PLB 1ea Porcelain Back Liner Panel MQRB4436 uses 5143PLE MQRB5143PLE or MQRB6961PLE 2ea Porcelain End Panels MQRB4436 MQRB5143 Dimensions MQRB6961 Dimensions...
Page 48: ...x Top Place End Panels into Firebox on top of the False Bottom and tilt into place at either end of the Firebox Replace the Liner Retainer Clips 4 Door Place the bottom of the door into the door retai...
Page 49: ...d of the Firebox Replace the Liner Retainer Clips MQRB4436 Uses 5143PLE MQRB5143PLE or MQRB6961PLE 2ea Porcelain End Panels 13 1 8 for MQRB6961 Note Warping and Discoloration of Porcelain or Painted M...
Page 50: ...Supports into shape Insert into space behind False Bottom at the center and at each end Step 5 Install Retainer Clips from Fluted Liners into upper back corners of firebox Step 6 Insert End Liners int...
Page 51: ...ace of the Side Fillers so long as the total amount of material applied is not thicker than 1 1 2 on the inside of the fireplace opening This will allow for removal of the Glass Door Access Panel Usin...
Page 52: ...ront Face Panel must be installed on the fireplace before surround can be installed 3 Remove Glass Door from fireplace 4 Hook lower ledge of Surround Frame onto the Lower Front Face Panel of the firep...
Page 53: ...or remove the grounding prong from this Before Servicing 1 Ensure all power supply is shut off 2 Label all wires prior to disconnecting when servicing control Wiring errors can cause improper and dan...
Page 54: ...rounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing controls Wir...
Page 55: ...te Use only 1 2 glass material on the burner Ember Glass Material from American Fireglass Maximum amount for MQRB4436 Natural Gas is 5 lbs Propane units 5 lbs Maximum amount for MQRB5143 Natural Gas i...
Page 56: ...5143 MQRB6961 MQEMBER Glowing Ember Chunks MQRBD1 or MQRBD2 Driftwood and Rock Kit Place rocks and logs onto False Bottom randomly MQ Rock2 or 3 30pc Rock Set Place rocks onto False Bottom randomly MQ...
Page 57: ...or MQ Ember Follow instructions for these accessories RBCB1 Cannonballs Assorted size and colors Place randomly as desired inside fireplace See NOTE above Can be used with MQ Glass MQ Rock MQ Stone o...
Page 58: ...G 2 LOG 5 LOG 3 LOG 4 LOG 1 LOG 1 LOG 2 LOG 2 LOG 3 LOG 3 LOG 4 LOG 4 LOG 5 LOG 5 NOTE For best flame pattern it is essential to spread supplied Crushed Glass or MQEMBER directly onto burner tube If s...
Page 59: ...n when removing broken glass Wear gloves Removal of the Glass Door NOTE A Door Latch Tool is provided to assist with removing and installing the glass doors See next page 1 Remove the door by unlatchi...
Page 60: ...ssary to use this tool it may prove helpful Fireplace Parts Are Removed for Clarity Only Step 1 Reach up into fireplace Step 2 Grasp Latch with Tool Step 3 Brace one hand between Tool and Glass Step 4...
Page 61: ...able Lower Face Panel Installers Note The Lower Face Panel on the valve side of the unit is shipped attached with only 3 screws for easy removal This allows all necessary gas line and electrical conne...
Page 62: ...appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than...
Page 63: ...ly the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then conti...
Page 64: ...Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replac...
Page 65: ...condition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure...
Page 66: ...tent or standing pilot system even if the main burner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Insp...
Page 67: ...njector near the top Propane injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sh...
Page 68: ...Gas Conversion for Modulator PART C 68...
Page 69: ...the side of the Air Shutter and rotate to the correct opening using a drill bit or tape measure Retighten screw 2 Remove the Main Orifice using a wrench and replace with the new Conversion Orifice wh...
Page 70: ...the side of the Air Shutter and rotate to the correct opening using a drill bit or tape measure Retighten screw 2 Remove the Main Orifice using a wrench and replace with the new Conversion Orifice wh...
Page 71: ...allow to cool before cleaning Only a Qualified service technician should service and repair this appliance 1 Remove Valve Heat Shield 2 Remove the Glass Door from the unit Loosen Liner Clips in Firebo...
Page 72: ...n while the IPI valve system must be rotated 180 for proper operation on the right side of the unit Note Take care not to damage the pilot tube during this operation MQRB6961 Wires and plumbing must n...
Page 73: ...he Air Shutter and rotate to the correct opening using a drill bit or tape measure Retighten screw 2 Remove the Main Orifice using a wrench and replace with the new Conversion Orifice which came with...
Page 74: ...he Glass Door from the unit Loosen Liner Clips in Firebox Top remove End Panels Remove DT screws and lift out the False Bottom 3 Remove the DT screws around the perimeter of the burner pan 4 Carefully...
Page 75: ...circuit is on low voltage side of transformer 3 Solid state transformer is designed to run halogen lamps ONLY 4 To remove leads from the 6 port terminal simply insert a pin to release the grip on the...
Page 76: ...it is on low voltage side of transformer 3 Solid state transformer is designed to run halogen lamps ONLY 4 To remove leads from the 6 port terminal simply insert a pin to release the grip on the wire...
Page 77: ...s Remotes Only The Remote Receiver may be located outside of the unit up to a maximum of 6 feet from either side of the fireplace An Extension Harness Part No 1001 P904SI is required The face of the R...
Page 78: ...ontrol Module and the IPI Module NOTE When using GTF Fan Module the 51 UHS must be used Remote Receiver IPI Module Fan Control Module Z36 FAN 120 VAC POWER VENT CONTROL MODULE LAMP TRANSFORMER ASSEMBL...
Page 79: ...ck This component permits the IPI system to operate without the need for an external AC Adapter power source The advantage to using the battery backup is that in the case of a power failure the applia...
Page 80: ...splay on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set...
Page 81: ...or 1002 P910si Electrode Flame Sensor 35 Length 5 1002 P302si IPI Ignition Board 6 1002 P850si AC Wall Adapter 7 1002 P12BH Battery Pack 8 1002 P912si Wiring Harness 9 1001 P166si Orifice Pilot NG 62...
Page 82: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 82...
Page 83: ...r units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harness as shown SCHEMATIC PICTURE NOTE...
Page 84: ...er Adapter P N 1002 P850si The Remote Receiver IPI or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the...
Page 85: ...lities Refer to the fan installation removal section for fan installation NOTE Fan Option is not available on some models of fireplace Check with your dealer NOTE This Configuration is not available o...
Page 86: ...clockwise to off Located behind the access panel 7 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above...
Page 87: ...13 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 14 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 15 1001 P168SI TC Orifice Pilot LP 977 168 35 IPI 16 1001 P280SI TC Tubing W Fittings 1 8 2 1...
Page 88: ...must be followed to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The PF2 Module may now be turned on off...
Page 89: ...ON OFF and the pilot is also out follow the procedures described in this manual to light the pilot To switch from IPI to CPI Mode 1 Turn the fireplace OFF using the ON OFF Key 2 Press the Mode Key Dis...
Page 90: ...Proflame 2 Remote Control 90...
Page 91: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode 91...
Page 92: ...92...
Page 93: ...u h 3 kW and 50 000 Btu h 15 kW 12 in 30 cm for appliances 50 000 Btu h 15 kW K Clearance to a mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally L Clearance abo...
Page 94: ...gth Therefore when installing the pipe expand it completely and then cut off the remaining length A flex pipe can be expanded to twice their shipped length e g 4ft to 8ft Do not use more than 2 couple...
Page 95: ...um horizontal run with the 90 degree bend at the fireplace flue outlet is 3 The maximum horizontal run is 20ft when the vertical run is 8ft Note 1 4 vertical rise is required for every 12 of horizonta...
Page 96: ...MQRB5143 MQRB6961 37 1 2 51 1 2 56 1 2 1 1 3 1 4 3 91 14 4 3 20 6 1 4 1 2 4 1 2 5 1 5 5 1 5 15 4 6 20 6 1 6 1 8 8 2 4 16 4 9 20 6 1 7 2 1 15 4 6 17 5 2 20 6 1 8 2 4 20 6 1 18 5 5 20 6 1 9 2 7 20 6 1 1...
Page 97: ...del Please contact your local dealer for more information Refer to Side Wall Venting for wall cutout information The Roof Support is used to secure the vertical venting as it penetrates the roof Pleas...
Page 98: ...he wall thimble Before joining pipes apply a bead of high temperature sealant Millpac to the end Then attach the inner pipe to the vent termination with sealant and secure it with the four screws prov...
Page 99: ...is to be located below grade a window well is recommended with adequate and proper drainage as per local codes Leave 2 clearance below snorkel to prevent water from entering the Snorkel Termination D...
Page 100: ...ng suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides and the lower edge lay on top of t...
Page 101: ...ght through roof support configuration b Flex bend configuration c Termination mounting 2 Top of Horizontal Vent 43ft Z57VT for MQRB436 Z57VT for MQRB5143 Z710VT for MQRB6961 Z710VT ONLY Restrictor Re...
Page 102: ...so remove the 2 screws at the front of the Flue Fig 1 2 Rotate the Flue Restrictor 180 Fig 2 Place the Flue Restrictor over the Flue start the 4 DT screws in the screw holes 3 For Vertical Venting 20...
Page 103: ...are permitted however Cold Climate Switch Standing Pilot Mode must NOT be used Seven 90 elbows are possible if the total horizontal is not more than 25ft and the vertical does not exceed 15ft Refer t...
Page 104: ...IRING HARNESS POWER VENT CONTROL MODULE Lamp Transformer housing may need to be moved toward valve Reposition Lamp Transformer housing Install Power Vent Control Module as shown Power Vent Control Mod...
Page 105: ...7FCL Flex Clamp 7 ZDV4SS Spring Standoff Spacer for Inner Pipe MQRB6961 VENTING AND VENTING ADAPTERS For fireplaces to be converted to hard pipe DuraVent DirectVent Pro etc at the fireplace Z69DFA Pip...
Page 106: ...Main Wiring Harness Assembly Extension Harness 20ft PVC58MV Power Vent Control Module Millivolt Box 58PVH P124 Double Pole Switch 58PVH P421 Timer Switch PVC58IPI Power Vent Control Module IPI Box 58...
Page 107: ...Porcelain Liner Back Single Side MQRB5143PLE Porcelain Liner Ends See Through Single Side Rocks Logs RBCB1 Cannonballs Assorted size and colors MQ46D Driftwood Log Set 3pcs MQ Stone Decorative Stones...
Page 108: ...torm Collar Flat ZDV7SC Storm Collar 7 Z57FK5 Flex Kit 5 7 Dia x 5 Expanded c w Springs Screws Mill Pac Z57FK8 Flex Kit 5 7 Dia x 8 Expanded c w Springs Screws Mill Pac Z57FK20 Flex Kit 5 7 Dia x 20 E...
Page 109: ...Stainless Steel Infinite Porcelain Liners MQRB5143PLB Porcelain Liner Back Single Side MQRB5143PLE Porcelain Liner Ends See Through Single Side Rocks Logs RBCB1 Cannonballs Assorted size and colors M...
Page 110: ...12 ZDVAF2 Flashing 7 c w Storm Collar 8 12 to 12 12 ZDVAF3 Flashing 7 c w Storm Collar Flat ZDV7SC Storm Collar 7 Z57FK5 Flex Kit 5 7 Dia x 5 Expanded c w Springs Screws Mill Pac Z57FK8 Flex Kit 5 7...
Page 111: ...r MQRB6924SSS Surround Trim Kit 74 7 8 x 24 Stainless Steel Infinite Porcelain Liners MQRB6961PLB Porcelain Liner Back Single Side MQRB6961PLE Porcelain Liner Ends See Through Single Side Rocks Logs R...
Page 112: ...illpac Z710FK8 Flex Kit 7 10 x8 Expanded Springs Screws Millpac Z710FK20 Flex Kit 7 10 x20 Exp Springs Screws Millpac ZDV7FC Flex Connector 7 Diameter ZDV10FC Flex Connector 10 Diameter ZDV7FCL Flex C...
Page 113: ...001 P216SI Thermocouple 290 216TC SIT 1001 P165SI Orifice Pilot NG977 165TC SIT 1001 P167SI Orifice Pilot LP977 167TC SIT 1001 P633SI Valve Nova LP Hi Lo 0820651 1001 P634SI Valve Nova NG Hi Lo 082065...
Page 114: ...001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Brass State Size 1000 306 Thermalcord Adhesive Back for Door Frame 36HB 123 Upper Door Spring 5143ZDV 400 Door Latch Tool 51MQ 123A Door Latch Assem...
Page 115: ...eep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety...
Page 116: ...emicals other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matchin...