MQRB6961 See Thru Framing
MQRB6961SK
Kit is required for a See Thru Installation.
Before you begin Framing
- Determine whether the
Wall Surface
will be flush with the face of the fireplace (Fireplace
and wall to be covered with Non-Combustibles, such as tile), or the
Framing
will be flush
with the face of the fireplace (Flat Wall appearance).
Note:
If using optional surround, maximum thickness for non-combustible material is 3/4”.
(Continued)
Framed Opening 71-1/2” x 45-1/2”
Framing style shown is for illustration purposes only.
This structure is NOT load bearing.
[Steel Stud Framing Shown]
Fireplace vent MUST maintain min. 1” clearance from combustible (Wood) framing.
However, if steel stud framing is used, 1” vent clearance is not required.
Also refer to these sections:
Clearance to Combustibles
Enclosure Heights
Venting
Note:
If Combustible (Wood) Framing Studs
are used, they must be rotated to allow
Min.1” Clearance from Airbox.
1” Min Clearance Around All Sides of Airbox