MQRB5143 Single Sided Framing
An
MQRB5143BK
Kit is required for a Single Sided Installation.
Before you begin Framing
- Determine whether the
Wall Surface
will be flush with the face of the fireplace (Fireplace
and wall to be covered with Non-Combustibles, such as tile), or the
Framing
will be flush
with the face of the fireplace (Flat Wall appearance).
Note:
If using optional surround, maximum thickness for non-combustible material is 3/4”.
(Continued)
Framing Style shown is for illustration purposes only.
This structure is NOT load bearing.
[Steel Stud Framing Shown]
17” Min. *
Airbox must maintain Min. 1” Clearance
From Combustible [Wood] Framing.
Wood Framing Studs Must be Rotated
Wood Framing Stud Rotated for Vent Clearance
FRAMED OPENING 53-1/2” WIDE x 38” TALL
CANTILEVER FINISHED MINIMUM OPENING IS 57-1/2” WIDE
1” Min Clearance Around All Sides of Airbox
* 17” Min.
Dimension is for
Wall Surface Flush
with fireplace.
Add 1/2” t
o this Dimension where a non-combustible wall surface will cover
the unit (see
Nailing Tab Guide
page also).
28