Kilowatt Labs 7100-48-B-3.3C-M-SD-A-FL User Manual Download Page 25

 

Sirius Capacitor Module 

 User Manual  

 

Model Number -7100-48-B-2C-M-SD-A-FL 

This manual is subject to change without notice and at the sole discretion of Kilowatt Labs, Inc.

  

Kilowatt Labs, Inc. 

www.kilowattlabs.com

 

 

   25 

 

 

 

High Module Temperature 

 

Front panel of Sirius Module has LCD and Reset Fault Button which act as multifunction 
buttons for monitoring and configuration. By using Reset fault Button and LCD, user can: 

 

Turn ON/OFF terminals of Module. 

 

Read Cell Voltages, Instantaneous Power, SOC, Terminal Voltage, Terminal 
Current, Terminal Temperature and Ambient Temperature. 

 

Recalibrating Current Measurement by configuring zero current values. 

 

Activating Terminals to make Module more secure at first operation. 

 

Snooze alarms in case of repeating Module alarms. 

 

LCD contrast can be configured anytime over SiriusVIEW Monitoring application. 

 

Sirius Module  can be used  with Power Save Mode, this feature can  be activated by 

SiriusVIEW Monitoring application. 

 

Front panel of Sirius Module also has 2 LEDs for letting user to know the status of module like: 

 

Communication LED (

Red

): Blinking while communicating. 

 

Terminal LED(

Green

): Active while terminal is ON, Inactive while terminal is OFF. 

11.3  Technical Features 

 

Sirius Module has one processor for alarm monitoring, communication and datalogging 
features. 

 

Sirius Module has internal memory card that is logging every 10 seconds the values of: 

 

Terminal Voltage 

 

Terminal Current 

 

Module SOC 

 

Ambient Temperature 

 

Terminal Temperature 

 

Time Stamp 

 

Internal logged data can be easily extracted over SiriusVIEW Monitoring application. Size of 
internal memory is 8GB and module can keep logging 30 days of data without interruption. 

 

User can delete and read SD card memory over SiriusVIEW Monitoring Application. 

 

Sirius Module has one of the best ADC to increase measurement accuracy as 6µV level. 

 

Sirius Module has advanced algorithm to control module in safest way. This algorithm can be 
upgraded by user with updating firmware of Sirius Module over SiriusVIEW Monitoring. 

 

Sirius Module firmware can be customized easily regarding user needs.  

 

Sirius Module has 

RS 232 

interface communicates with Host PC for: 

 

Measurement Monitoring 

 

Alarm Monitoring 

 

System Configuration 

 

Measurement Calibration 

 

Manual/Auto Data Logging\Module firmware updating 

Summary of Contents for 7100-48-B-3.3C-M-SD-A-FL

Page 1: ...SIRIUS CAPACITOR MODULE User Manual Model number 7100 48 B 3 3C M SD A FL Version 1 0 Release Date May 2019...

Page 2: ...att Labs Inc Kilowatt or the Company Specifications in this Manual are subject to change without notice While every attempt has been made to make the Manual accurate and up to date users are cautioned...

Page 3: ...ppearance 7 3 2 2 Mechanical Drawings 7 3 2 3 Dimension and Weight 9 3 3 Front Panel Description 9 4 Module Installation 13 4 1 Inspection 13 4 2 Safety Gear 14 4 3 Unpacking and Contents Check 14 5 O...

Page 4: ...ions for unpacking mounting installation and operation of a Sirius module Please read this manual carefully before operating the system and follow all warnings and safety instructions to prevent accid...

Page 5: ...mstances o Do not connect or disconnect terminals from the Module without first disconnecting the load o Do not touch the terminals with conductors while the Module is charged Serious burns shock or m...

Page 6: ...ped to you either by air or by sea If you receive the Modules shipped by air please follow the instructions given below Carefully remove the nails from all the four sides of the wooden box and open it...

Page 7: ...A FL This manual is subject to change without notice and at the sole discretion of Kilowatt Labs Inc Kilowatt Labs Inc www kilowattlabs com 7 3 2 Product Overview 3 2 1 Appearance The appearance of th...

Page 8: ...le User Manual Model Number 7100 48 B 2C M SD A FL This manual is subject to change without notice and at the sole discretion of Kilowatt Labs Inc Kilowatt Labs Inc www kilowattlabs com 8 Top View Sid...

Page 9: ...cription 1 Circuit Breaker C100A Circuit Breaker 2 2 Fault Reset Fault Reset Button 3 LCD 16 2 LCD 4 Aux Auxiliary USB 5 Comm Connector Communication Connector USB 6 Comm Status Communication Status L...

Page 10: ...and Instantaneous Power e Press the Fault Reset button to see the individual cell voltages Checking for individual Cell Voltage When the fault reset button is pressed the LCD after displaying the stat...

Page 11: ...the LCD displays the following message it means that cell balancing has been disabled Step 5 To make the current zero follow the steps below When the current is not zero the LCD will display the follo...

Page 12: ...ched ON from the circuit breaker the Module gets power and the LCD shows the following message after 3seconds under normal operation After 1 second the following two LCD screens gets switched between...

Page 13: ...ON The protected terminal is active Green OFF The protected terminal is not active 7 Protected Terminal This is the output terminal of the module which has electronic switch protection that is limited...

Page 14: ...equirements of the end use application Installation must be performed by professional installers only Switch off the system and check for hazardous voltages before altering any connection Sirius modul...

Page 15: ...ction of Cables to Anderson Connectors First connect the Anderson Connector to the Cables of the Module by following the steps below Take Anderson Connector as shown in the picture Strip the insulatio...

Page 16: ...nc www kilowattlabs com 16 Hold the housing and place the connector into the back of the housing and push it tightly Make sure the Anderson connector is firmly hooked Step 2 Connecting the Load Connec...

Page 17: ...ble to see the terminal status LED OFF 4 Wait till the LCD screen on the Module displays initial values 5 Press and hold the fault reset button after 3 seconds the terminal status LED will change to G...

Page 18: ...nication andmonitoring 3 Turn on the Sirius module by pressing the fault reset button 4 Wait till the LCD screen on the Module displays initial values 5 Double click on the SiriusVIEW application to e...

Page 19: ...Recovery Procedure When the Module voltage drops below a certain threshold the control electronics are turned OFF To restart the control electronics follow the steps below 1 Use the Unprotected termi...

Page 20: ...ed Voltage 44V 54V 8 Connecting the Modules in Parallel or in Series The capacity or voltage of the Modules can be increased by connecting them in parallel or series respectively 8 1 Parallel Connecti...

Page 21: ...l Modules Take out the output positive and output negative from the respective commonpoint 8 2 Series Connection of Sirius Modules A maximum of 8 modules can be connected in series with a Module Combi...

Page 22: ...st module and Output Negative from the last module 9 Automatic Safety Shutdown The Module will automatically shut down under any excessive use conditions in order to prevent damage to the itself and c...

Page 23: ...Module reaches the minimum voltage and it is in standby mode the LCD will display this message every 30 seconds When the Module has reached the minimum voltage and the Module is connected to a load t...

Page 24: ...the Module temperature comes below 80 C Now turn ON thecircuit breaker Please Remove Charger Please Connect Charger This happens when there is some residual current In this event the Module gives alar...

Page 25: ...dule like Communication LED Red Blinking while communicating Terminal LED Green Active while terminal is ON Inactive while terminal is OFF 11 3 Technical Features Sirius Module has one processor for a...

Page 26: ...www kilowattlabs com 26 Internal SD card reading refreshing Statistical Analyzing Graphical results 12 Shelf Life Shelf life is the life of the Module in years from the date it is manufactured to the...

Reviews: