background image

PWR Series Setup Guide

Checking the Package Contents

When you receive the product, check that all accessories are included and that the accessories have not been damaged during transporta-
tion. If any of the accessories are damaged or missing, contact your Kikusui agent or distributor. The power cord varies depending on the type.

Accessories

M3 sensing terminal screws

M3 screws for chassis connection wire

2 pcs.

[M3-112-012]

J1

protection socket

1 pc.

[84-49-0110]

J1 

lock lever

1 pc.

[83-06-5060]

Plug

NEMA5-15

Rating

125Vac/10A

[85-AA-0003]

Plug

NEMA5-15

Rating

125Vac/10A

[85-10-0740]

Pulg

: CEE7/7

Rating: 250Vac/10A

[85-10-1070]

Pulg: GB1002

Rating: 250Vac/10A 

[85-10-0790]

or

or

1 pc.

 [M3-112-012]

1 pc.

 [M3-112-015]

CD-ROM (1 pc.)

Setup Guide (This guide, 1 pc.)

Quick Reference

English 1 pc. , Japanese 1 pc.

Safety information (1 pc.)

Power cord for the 400W/800W type

Power cord for the 1600W type (with cable clamp and no plug)

M8 output terminal screws

2 sets

M4 output terminal screws

2 pcs.
[M3-112-026]

OUTPUT terminal cover

TP-BUS connector

1 pc.
[84-61-5102]

[M1-100-011]

[M5-101-007]

[M4-100-007]

1 set

[Q1-500-077]

Cable clamp: [P1-000-055] 1 pc.
Fastening plate: [D6-750-001] 1 pc.

Cable: [85-10-1010] 1 pc.

EMI core: [96-01-0180] 1 pc.

Accompanying screws B: [M3-112-017] 2 pcs.

Accompanying screws A: [M3-112-015] 2 pcs.

Accompanying nuts: [M8-500-003] 2 pcs.

The power cord that is provided varies depending on 

the destination for the product at the factory-shipment.

These parts are installed in body.

or

Summary of Contents for PWR1600H

Page 1: ...al remote control function through TP BUS Twist Pair BUS communication The total length of TP BUS is 200 m By combining with Kikusui s PIA4800 Series Power Sup ply Controller systemization for applica...

Page 2: ...GB1002 Rating 250Vac 10A 85 10 0790 or or 1 pc M3 112 012 1 pc M3 112 015 CD ROM 1 pc Setup Guide This guide 1 pc Quick Reference English 1 pc Japanese 1 pc Safety information 1 pc Power cord for the...

Page 3: ...lost or soiled a new copy can be provided for a fee To replace or purchase a manual please contact your Kikusui agent or distributor At that time inform your agent or distributor of the Part No writt...

Page 4: ...igured in a way that satisfies the equation output voltage x output current rated output voltage the actual output is limited by the power limit approx 105 of the rated output power and the output vol...

Page 5: ...Rated output current Extended operating area Intermittent extended operating area Maximum output current Continuous extended operating area Extended operating area Continuous output is possible At amb...

Page 6: ...d the product to prevent electric shock Connect the ground terminal to earth ground Connecting the Power Cord Precautions Concerning Installation This product cannot be used while it is on its side Th...

Page 7: ...difficult consult your Kikusui agent or distributor The power cord with a three prong plug is used to disconnect the PWR from the AC line in an emergency Connect the power plug to an easily accessibl...

Page 8: ...e corre sponding input terminals L N and GND are correct Note Turn off the circuit breaker of switchboard to disconnect the PWR from the AC line in an emergency Circuit breaker of switchboard requirem...

Page 9: ...es with the input rating of the PWR The voltage that can be applied is any of the nominal power supply voltages in the range of 100 VAC to 240 VAC The frequency is 50 Hz or 60 Hz 2 Check that the POWE...

Page 10: ...switch is turned off 2 Check that the power cord is correctly connected 3 Turn the POWER switch on Push the side of the POWER switch to turn the PWR on If an odd sound odd odor fire or smoke occurs a...

Page 11: ...ff The PWR stores the panel settings excluding output on off condi tion immediately before the POWER switch is turned off For these items the PWR starts up using the settings that existed when the POW...

Page 12: ...e Ammeter reading average value Preset constant current value Ammeter reading average value Load that generates reverse current to the power supply The PWR cannot absorb reverse current from the load...

Page 13: ...PWR and the load in series CAUTION To protect the load and the PWR select a DRP that com plies with the following conditions Reverse voltage withstand capacity of at least twice the rated output volta...

Page 14: ...mbient temperature and thermal resistance to the outside Table shows the allowable capacity of current that can flow through a heat resistant PVC wire single wire having a maximum allowable temperatur...

Page 15: ...voltage drop exceeds this level wires having a greater sectional area should be used Nominal cross sectional area of wires and allowable currents Nominal Cross Sectional Area mm2 AWG Reference Cross S...

Page 16: ...of AWG18 or higher to make the connection This M3 screw is fastened to the pos terminal before factory shipment If you want to connect the chassis connection wire to the neg output terminal as shown...

Page 17: ...out screws 2 Align the hook of the bottom cover to the groove lo cated to the side of the output terminal 3 Align the bottom cover with the top cover and fix them in place using the screws attached to...

Page 18: ...utput terminal on the front panel Do not use the terminal with the front output terminal cover removed In addition be sure to attach the OUT PUT terminal cover on the rear panel Possible overheating o...

Page 19: ...indows and Visual Basic are registered trademarks of Microsoft Corporation in the United States and or other countries All company names and product names used in the PWR manual are trademarks or regi...

Page 20: ...i Name of hazardous materials and symbol of element in the equipment and quantity Name of part Hazardous material and symbol of element Pb Hg Cd Cr VI PBB PBDE Printed circuit board assemblies Interna...