PFX2000
Setup 1-9
Connecting the power cord of the PFX2332 Unit Frame
The power cord of the PFX2332 cannot be removed from the unit.
Keep in mind that the product is designed for Overvoltage Category II.
• Due to the large power consumption, the PFX2332 cannot be connected
using a plug. Be sure to connect the PFX2332 to a switchboard.
1.
Check that the AC power supply meets the AC input speci
fi
cations of
the PFX2332.
2.
Turn off the power switch.
3.
Attach crimp terminals to the power cord.
4.
Connect the power cord to the switchboard.
Be sure to turn off the switchboard switch beforehand.
Fig. 1-3Power cord of the PFX2332
Nominal input rating: 200 VAC to 240 VAC, 50/60 Hz, single phase
Power consumption:
4
000 VA (at rated output)
WARNING
N:
White or blue
L:
Black or brown
(GND):
Green or green/yellow