4
PAT-T
SYSTem subsystem
SCPI Command
Setting
Default
Resp.
*RST
Description
R/W
†
Program header
Parameter
Unit
SYST
:CONF
:BTR
[:IMM]
Breaker trip.
W
3
:PROT
bool
OFF
NR1
Yes
Turns breaker trip on/off when the
OCP/OVP activates.
R/W 3
:SHUT
bool
OFF
NR1
Yes
Turns the breaker trip on/off when the
SD signal is applied.
R/W 3
:PAR
NRf
1 to 5
*1
1
NR1
Setting the number of units in Master-
Slave Parallel Operation.
R/W 3
:PST
char
NORM | INV
NORM
char
Sets the status signal of the power on/
off.
R/W 3
:RSEN
NR1
Queries the sensing switch status.
R
3
:MSL
char
MAST | PAR
MAST
char
Sets the status during parallel
operation.
R/W 3
:MPR
*2
char
CV | CC
CV
char
Sets the output-on startup state.
R/W 3
:SPH
*3
bool
OFF
NR1
Sets the phase input mode.
R/W 3
:TRAC
bool
OFF
NR1
Sets whether to display or hide the
communication error.
R/W 3
:ERR[:NEXT]?
string
Read the error information.
R
3
:KLOC
bool
NR1
Panel operation lock.
R/W 1
:LOC
Sets to local.
W
1
:OPT
char
Queries the option interface board.
R
3
:REM
Sets the operation to remote. Locks
the panel keys except the LOCAL
switch.
W
3
:RWL
Sets the operation to remote. Locks
the panel operation.
W
3
:VERS
Queries the SCPI specification version
with which the PAT complies.
R
1
*1.
On the PAT850-9.4T, the settings are 1 | 2
*2.
The command is available for 8 kW type products only.
*3.
The command is available for 4 kW type products only.
PAT-T series Communication Interface Manual
KIKUSUI ELECTRONICS CORP.