2.1 Intended use
The sampling valve is used to remove or vent liquid or gaseous media from tanks or pipe system in
plants of the food and drink industry, pharmaceutical and chemical industries as well as in biotech-
nology.
2.2 General notes
NOTICE - observe the operating instructions
To avoid danger and damage, the fitting must be used in accordance with the safety instructions
and technical data contained in the operating instructions.
NOTICE
All data are in line with the current state of development. Subject to change as a result of tech-
nical progress.
2.3 General safety instructions
WARNING
Risk of injury by outflowing medium
Dismantling the valve or valve assemblies from the plant can cause injuries.
–
Medias flowing through the leakage drain outlet are to be drained off without splashing
into a discharge arrangement.
–
Carry the disassembling only if when the plant has been rendered pressure-less and free
of liquid and gas.
CAUTION
Risk of burning whilst flaming the valve!
There is a risk from burns of parts of the body.
Ø
The valve gets very hot under flaming. When flaming the valve,
–
wear suitable protective gloves and protective clothing
–
local fire safety regulations must be followed.
CAUTION
Destroy of the valve seal when flaming the valve!
The valve seal can be destroyed by excessive heat supply.
Ø
The valve must be flamed generally by trained personnel.
–
The instructions in the chapter “Sterilization” must be observed.