1994 to 2008
Specifications:
Time Delay:
Input:
On Time
Adjustable from 50 to 500 Milliseconds
Opera�ng
Voltage
120 +-10% VAC, 50/60 Hz
Off Time
Adjustable from 1.5 to 30 Seconds
Op�onal
Voltage
220 +-10% VAC, 50/60 Hz
Output:
Protection:
Type
Solid State Switch rated at 200 VA max. per
output (posi�on of program wire
determines number of outputs)
Transi
ent voltage
Short Circuit Protec�on
30 Joule Varistor
3 amp fuse
Environmental:
Opera�ng Temperature:
-
40 degrees to 150 degrees F
(-
40 degrees to 66 degrees C)
Model
Max. No. Of
Outputs
Size of NEMA 4
Enclosure required
Programmable
No. of Outputs
DNC-T2010-A10
10
10" x 8"x 4"
3 - 10
DNC-T2020-A10
20
12" x 10"x 5"
11 - 20
DNC-T2032-A10
32
14" x 12"x 6"
17 - 32
1994 to 2008
Specifications:
Time Delay:
Input:
On Time
Adjustable from 50 to 500 Milliseconds
Opera�ng
Voltage
120 +-10% VAC, 50/60 Hz
Off Time
Adjustable from 1.5 to 30 Seconds
Op�onal
Voltage
220 +-10% VAC, 50/60 Hz
Output:
Protection:
Type
Solid State Switch rated at 200 VA max. per
output (posi�on of program wire
determines number of outputs)
Transi
ent voltage
Short Circuit Protec�on
30 Joule Varistor
3 amp fuse
Environmental:
Opera�ng Temperature:
-
40 degrees to 150 degrees F
(-
40 degrees to 66 degrees C)
Model
Max. No. Of
Outputs
Size of NEMA 4
Enclosure required
Programmable
No. of Outputs
DNC-T2010-A10
10
10" x 8"x 4"
3 - 10
DNC-T2020-A10
20
12" x 10"x 5"
11 - 20
DNC-T2032-A10
32
14" x 12"x 6"
17 - 32
25
Kice Industries, Inc.
FLT-M03-0002
012420
Filter Operation & Start-Up Procedure Continued
Figure 15