background image

Assemble units as described herein only. To do otherwise 
may result in instability. All screws, nuts and bolts must be  
tightened securely and must be checked periodically after  
assembly. Failure to assemble properly, or to secure parts 
may result in assembly failure and personal injury.

3

Toggle

®

 Tables - Dual Motor Height-Adjustable Base, Model EL

Assembly Instructions

Table Wiring

Note: 

Control cables can be routed 

differently than shown. 24” deep 

tables must have the control box 

mounted between the cross-tube 

assemblies, which requires 

installation of the “optional key pad” 

(Figure 4). All 30” & 36” tables may 

have the control box mounted either 

between the cross-tube assemblies, 

centered behind the cross-tube 

assemblies or one of two locations 

at the front of the table (Detail A). 

Mounting to the front of the table 

does not require the use of the 

“optional key pad”. Follow directions 

appropriate to control box mounting 

location.

Note:

 When plugging leg control 

cord ends in, make sure to push in 

straight to avoid bending any pins 

in the electrical control box or leg 

motor. The plug will click when it is 

locked into place. 

Note: 

If any plug needs to be 

removed, make sure power cord 

is un-plugged from power source 

outlet first. Then push down 

on release tab on the control 

cable plug while simultaneously 

pulling on the end to remove 

from the socket. 

1. 

Leg Cord - Long:

 Plug the 

longer leg control cord into one 

of the two rectangular sockets on 

the control box, then route cord 

to the leg farthest from control 

box. Use cut outs in the table 

to route under the cross tubes 

and/or use zip ties secured with 

screws at pre-drilled locations. 

Plug other end of the longer leg 

control cord into the open socket 

on leg motor (Figure 4).

2. 

Leg Cord - Short:

 The next 

rectangular socket on the control 

box is utilized by the shorter leg 

control cord. Plug short leg cord 

into control box and route to the 

leg motor socket that is closest 

to the control box. Use cut outs 

in table to route under the cross 

tubes. Plug other end of the 

shorter leg control cord into open 

socket on leg motor (Figure 4).

3. 

Optional

 

Key Pad: 

The key pad 

can be mounted on the front side 

of tabletop (Figure 4). Using 

  pre-drilled holes, secure key pad 

to tabletop with two M4.2 x 19 

  flat head screws at 1.5 ft/lb. 

Note:

 Do not overtighten screws. 

Once key pad is mounted, route 

attached cord to control box. Use 

Figure 4 for cord routing reference 

and for the optimal usage of 

zip-tie points. Once the key pad 

cord is routed to control box, plug 

cord into the round socket on box 

(Figure 4).

Note: 

Make sure all cables are 

routed correctly and plugged into 

correct sockets on control box 

and leg motor locations before 

installing zip-ties. 

4. 

Zip-ties:

 Six zip-ties are included 

for keeping cords tight to table, 

but it is not necessary to use all 

six. Using Figure 4 for reference, 

wrap the zip-ties around the loose 

cords and then mount the zip-tie 

to the tabletop with a M5.5 x 22 

pan head screw into the  

pre-drilled holes. The zip-ties 

have a built in mounting hole 

which must lay flat onto surface. 

Make sure zip-ties and cables are 

snug before moving to next step.

5.  

Power Cord:

 The final cord to 

be installed is the power cord. 

Plug power cord into remaining 

open socket which is tri-lobe in 

shape. Cord should not be  

zip-tied or routed through cut outs 

on table (Figure 4). Do not plug it 

into power source at this time. 

6.  If optional wire trough was 

specified for installation, go now 

to page 4. If no wire trough is 

specified, carefully turn table to 

the upright position with the help 

of another person. Adjust glides 

on feet to level the table. Plug the 

power cord into a grounded outlet 

power source (Detail C). 

Note: 

Power cord must have enough 

slack so the table can cycle 

through its entire range of motion.

7.  

The table must be “zero set” 

prior to being placed into 

service. Refer to table “zero 

setting” instructions in the 

trouble shooting guide on 

page 8.

 

8.  If the table is not operating 

properly, see the trouble shooting 

guide in this instruction.

M4.2 x 19

flat head screw

M5.5 x 22

pan head screws

leg control cord

(long)

leg control cord

(short)

power

cord

Detail B - 30” & 36” Table with Front Control Box

Figure 4

leg control cord

(long)

key pad

cord

leg control cord

(short)

power

cord

key pad

(optional)

leg motor

control

box

control

box

M4.2 x 19

flat head screw

(max torque is 1.5 ft/lbs)

M5.5 x 22

pan head screws

(six)

zip-ties

(six)

cross-tube

assembly

This product is for use on a nominal 120-volt circuit and has a grounding plug 
that looks like the plug illustrated in Detail C. Make sure that the product is 
connected to an outlet having the same configuration as the plug. No adapter 
should be used with this product.

Detail C

grounding

pin

grounded

outlet

GROUNDING INSTRUCTIONS

Summary of Contents for Toggle EL

Page 1: ...7 5 ft lb Figure 1 4 If casters are required twist both adjustable glides out of the foot Locking and non locking casters are supplied Locking casters should be located toward the front user side of t...

Page 2: ...o the underside of the tabletop centered between the cross tube assemblies Position the control box over the pre drilled mounting holes and secure using two M5 5 x 22 pan head screws Figure 2 9 For 30...

Page 3: ...lb Note Do not overtighten screws Once key pad is mounted route attached cord to control box Use Figure 4 for cord routing reference and for the optimal usage of zip tie points Once the key pad cord...

Page 4: ...g locations If the control box is mounted to the front user side of the table reference Figure 6 Mounting to the front of the table does not require the use of the optional key pad Figure 6 If the con...

Page 5: ...l box is mounted between the cross tube assembly reference Figure 5 for placement of the wire trough A 30 or 36 depth tabletop is the only depth which will allow a control box to be in the following l...

Page 6: ...he pre drilled mounting holes of the R8 power module with the drilled mounting holes underneath the tabletop Secure the R8 power module to the tabletop using four 8 x 3 4 wood screws Take care to not...

Page 7: ...e clamp location drill a pilot hole to a depth of 3 4 making sure to not drill too deep piercing the tabletop Figure 10 3 Nest the power cord inside the cable clamps Position the cable clamps over the...

Page 8: ...ow table to cool Table Base moves erratically or is tilted one leg moves one does not Control box is not properly synchronized with the legs Ensure that all cables connections are fully seated Then pe...