Assemble units as described herein only. To do otherwise 
may result in instability. All screws, nuts and bolts must be  
tightened securely and must be checked periodically after  
assembly. Failure to assemble properly, or to secure parts 
may result in assembly failure and personal injury.

Assembly Instructions

Toggle

® 

Tables 

Dual Motor Height-Adjustable Base, Model EL

January 2019

1. Carefully remove contents from 

packaging, set out on a soft, clean 

surface and refer to Figure 1 

  to identify the parts required for 

assembly.

2.  Position two cross-support tubes 

(with mounting tabs down and 

facing inward), and one 

end-support tube out as illustrated. 

Place a leg column assembly over 

the three tubes, aligning all six 

mounting holes on the flange of the 

column with the mounting holes on 

the three tubes. Using six  

M8 x 12 button head machine 

screws torqued to 9.5 ft/lb, secure 

the flange of the leg column to the 

three base tubes (Figure 1).

3.  Mount the foot to the leg column 

by first positioning a plastic foot 

plate over the mounting location 

on the leg column. The plastic foot 

plate should be oriented so the 

raised flange faces down on the 

leg to nest the foot plate in place. 

Position a foot over the flat face 

of the foot plate, aligning holes 

in underside of the foot with the 

mounting holes in the column, and 

secure foot to column with four 

M6 x 35 socket head cap screws. 

Torque to 7.5 ft/lb (Figure 1).

4.  If casters are required, twist both 

adjustable glides out of the foot. 

Locking and non-locking casters 

are supplied. Locking casters 

should be located toward the 

front, user side of the table for 

easy access while the non-locking 

casters are located to the back. 

Using four #10-24 x 

3

/

8

” Torx 

screws, carefully secure the casters 

to the foot (Detail A).

5. Repeat steps 2 & 3 for second leg 

assembly and step 4 if casters are 

required (Figure 1).

6. Position two leg-to-leg spanners 

with channel opening face up, then 

slide both spanners into the open 

ends of each base tube of both base 

assemblies. Slide bases together, 

but do not secure with set screws at 

this time (Figure 1).

ATTENTION:

 Following assembly, 

table must be “zero set” 

prior to being placed into service

.

 Failure to do so can cause 

table to malfunction. 

Table “Zero Setting”

:

 

Press and hold the Up button for 

two seconds then release. Next, press and hold the Down 

button until table has reached its lowest position then release 

Down button. Then, press the Down button again and hold for 

approximately 10 seconds. The table now re-set at its “Zero 

Setting” position and is ready to operate. 

leg-to-leg

spanners

leg

column

foot

foot

plate

M8 x 12

button-head

machine screw

M8 x 12

button-head

machine screw

mounting

flange of

motor housing

end-support

tube

cross-support

tube

set screw

holes

M6 x 35

socket head

cap screw

M6 x 35

socket head

cap screw

Figure 1

Detail A

adjustable

glide

#10-24 x  /

Torx head

screws

3

8

"

foot

non-locking

caster

locking

caster

adjustable

glide

Motor-Operated Furnishing  

-FOR COMMERICAL USE ONLY-

Summary of Contents for Toggle EL

Page 1: ...7 5 ft lb Figure 1 4 If casters are required twist both adjustable glides out of the foot Locking and non locking casters are supplied Locking casters should be located toward the front user side of t...

Page 2: ...o the underside of the tabletop centered between the cross tube assemblies Position the control box over the pre drilled mounting holes and secure using two M5 5 x 22 pan head screws Figure 2 9 For 30...

Page 3: ...lb Note Do not overtighten screws Once key pad is mounted route attached cord to control box Use Figure 4 for cord routing reference and for the optimal usage of zip tie points Once the key pad cord...

Page 4: ...g locations If the control box is mounted to the front user side of the table reference Figure 6 Mounting to the front of the table does not require the use of the optional key pad Figure 6 If the con...

Page 5: ...l box is mounted between the cross tube assembly reference Figure 5 for placement of the wire trough A 30 or 36 depth tabletop is the only depth which will allow a control box to be in the following l...

Page 6: ...he pre drilled mounting holes of the R8 power module with the drilled mounting holes underneath the tabletop Secure the R8 power module to the tabletop using four 8 x 3 4 wood screws Take care to not...

Page 7: ...e clamp location drill a pilot hole to a depth of 3 4 making sure to not drill too deep piercing the tabletop Figure 10 3 Nest the power cord inside the cable clamps Position the cable clamps over the...

Page 8: ...ow table to cool Table Base moves erratically or is tilted one leg moves one does not Control box is not properly synchronized with the legs Ensure that all cables connections are fully seated Then pe...

Reviews: