Troubleshooting 43
Figure 3-12. Test Header Jumper Positions
Post-Repair Calibration
When Required
Calibration is required annually and also whenever certain components are replaced. If components in any of the circuits
listed below are replaced, the supply must be recalibrated.
Note
For calibration procedures, see Appendix A of the Operating Manual.
Location
Component
A10 Control Board
CV/CC DACs/operational amplifiers, CV/CC control circuit amplifiers, readback
DAC/operational amplifier, readback comparators.
A1 Front Panel Assy
A1 Front Panel Board or EEPROM AlU6.
Note
: If either of these front panel components is replaced, the power supply must first be
reinitialized before calibration (see "EEPROM Initialization" ) .
Inhibit Calibration Jumper
If
CAL DENIED
appears on the display when front panel calibration is attempted (or error code 1 occurs when GPIB
calibration is attempted on a Systems Supply), the INHIBIT CAL jumper (see Figure 3-15) is installed. This prevents the
power supply calibration from being changed. To calibrate the power supply first move this jumper from the INHIBIT CAL
position to the NORM position.
Calibration Password
In order to enter the calibration mode, you must use the correct password as described in Appendix A of the Operating
Manual. As shipped from the factory, the supply's model number (e.g., "6681") is the password. If you use an incorrect
password,
PASSWD ERROR
appears on the display during front panel calibration, or error code 2 occurs during GPIB
calibration, and the calibration mode is disabled. If you do not know the password, you can recover the calibration function
by restoring the preset factory calibration constants as described below.
Summary of Contents for 669 A Series
Page 2: ...Service Manual Keysight Series 669xA GPIB DC Power Supplies ...
Page 3: ......
Page 27: ......
Page 56: ...Troubleshooting 53 Figure 3 15 3 Inch Front Panel Frame Assembly ...
Page 57: ...54 Troubleshooting Figure 3 16 Assembly A10 Exploded View ...
Page 58: ...Troubleshooting 55 Figure 3 17 Assembly A10 Exploded View 6690A ...
Page 59: ...56 Troubleshooting Figure 3 18 Assembly A10 Exploded View 6691A 6692A ...
Page 60: ...Troubleshooting 57 Figure 3 19 Three Phase Line Choke Subchassis Wiring ...
Page 61: ...58 Troubleshooting Figure 3 20 24 Volt Fan Transformer ...
Page 77: ...74 Diagrams Figure 6 1 Test Point Waveforms for Table 6 3 sheet 2 of 2 ...
Page 79: ...Figure 6 3 A1 Front Panel Board Assembly Diagram ...
Page 81: ...Figure 6 5 A2 GPIB Board Component Location ...
Page 83: ...Figure 6 7 A3 FET Board Component and Test Point Location ...
Page 87: ...Figure 6 11 A4 AC Input Board Component and Test Point Location 12 9 10 11 ...
Page 89: ...Figure 6 13 A5 DC Rail Board Component and Test Point Location 13 14 ...
Page 91: ...Figure 6 15 A6 Bias Board Component and Test Point Location 15 16 17 18 19 19 20 22 ...
Page 94: ...Figure 6 17 Power Mesh Schematic Diagram All Models ...
Page 103: ......