KEY RK-2001W2N Operation Manual Download Page 6

6

parameter value with the < or > button we choose [End] and pres OK or wait for 1

minute – the controller will exit the service mode and will start indicating the

temperature of the water in the boiler.

Table 2. Service parameters list.

Disp.

Parameter

Min Max Step Factory

default

Π100 Fan max work power or max power when Πr 0-10.

50

100 10%

100

n 40 Minimum fan power.

20

40

10%

40

Πh 2 Fan speed decrease coefficient.

2

10

1

2

Πr 0 Automatic fan speed control and time of fan start.

--, 0

10

1

0

Πn15 Fan work time.

--, 5

60

1s

15

Πu 6 Fan pause time.

1

99 1min

6

r 50

Maximum fan speed during boiler start.

50

100 10%

50

rh 5

Boiler start completed hystaresis.

1

45

1ºC

5

P 40 Central heating pump launch temperature.

30

70

1ºC

40

Ph 2 Central heating pump hysteresis.

1

10

1ºC

2

Pc 2 The work mode and pause time of CH pump.

--, 1 99, F 1min

2

u 50 Tap hot water desired temperature.

30

60

1ºC

50

uh 5 Hot water heating hysteresis.

1

9

1ºC

5

ur 0

Work mode of hot water pump:

0 - no hot water,

1 - hot water priority,

2 - no hot water priority,

3 - mixing pump.

0

3

1

0

L 45 Minimum boiler temperature.

30

65

1ºC

45

H 85 Maximum boiler temperature.

80

90

1ºC

85

h 2

Boiler temperature hysteresis.

1

10

1ºC

2

A 99 Boiler overheating temperature.

90

99

1ºC

99

Fd2h Fuel shortage testing time with burning.

--, 1 99, 4h 1min

2h

Fb2h Fuel shortage testing time in WORK mode and

burning out.

--, 1 99, 4h 1min

2h

Ar 0

Work mode of extra output:

0- output turning on extra boiler,

1- alarm output,

2- output controlling mixing valve,

3- output controlling emergency cooling system,

4- output controlling extra devices turning on during

work of blow-in fan.

0

4

1

0

Prod Return to factory defaults.

outP Central heating pump testing.

outP out1

outΠ Fan output testing.

outΠ out2

outr

Additional output testing.

outr out3

outu Hot water pump output testing.

outu out4

End Exit the service mode.

In the table above, the first column represents example display indications, in the

next columns there are: parameter description, minimal amount, maximum amount

allowed to set, step of the parameter during the setup. The last column shows factory

defaults to which you can return by choosing [Prod] option.

Summary of Contents for RK-2001W2N

Page 1: ...OPERATION MANUAL RK 2001W2N SOLID FUEL FIRED BOILER TEMPERATURE CONTROLLER Version C112...

Page 2: ......

Page 3: ...ate sockets in the rear of the controller The temperature sensor should be placed in a measurement hole in the boiler Picture 2 shows diagram of electrical connection of the controller CAUTION Before...

Page 4: ...50 c hold up of burning in WORK mode 50 U heating of hot water in SUMMER mode 70 d total bacteria control heating up of hot water up to 75 C 4 Setting up the user parameters Holding OK button enters t...

Page 5: ...tton E g 70 d will appear on the display After reaching 75 C in the hot water tank the controller will return to its state before choosing this option CAUTION the total bacteria control function can s...

Page 6: ...r 1 hot water priority 2 no hot water priority 3 mixing pump 0 3 1 0 L 45 Minimum boiler temperature 30 65 1 C 45 H 85 Maximum boiler temperature 80 90 1 C 85 h 2 Boiler temperature hysteresis 1 10 1...

Page 7: ...ter When this parameter is set to a value between 0 and 10 it defines time in minutes of gradual increase of fan speed from its minimum value n 40 to value r 50 for smooth start Fan work time n15 time...

Page 8: ...ater pump working with priority ur 2 value hot water tank working without priority ur 3 value means controlling of the returning water mixing pump in the boiler with the launch temperature of u 50 and...

Page 9: ...rm by pressing STOP button 5 7 Additional output Additional output work mode Ar 0 the controller is equipped with a multipurpose output that can work in one of following modes Ar 0 mode output may con...

Page 10: ...put allowing to connect any kind of room thermostat with contact output When temperature in the room is below desired temperature the central heating pump is turned on and the room thermostat indicato...

Page 11: ...oiler remove the controller from the slot in the boiler disconnect all connectors with leads from the controller 9 Specifications Voltage 230V 10 50Hz Power consumption 4VA Temperature measurement ran...

Page 12: ...12 Picture 2 RK 2001W2N connection diagram...

Page 13: ...p hot water desired temperature uh 5 Hot water heating hysteresis ur 0 Work mode of hot water pump 0 no hot water 1 hot water priority 2 no hot water priority 3 mixing pump L 45 Minimum boiler tempera...

Page 14: ...14...

Page 15: ......

Page 16: ...Producer P W KEY 11 200 Bartoszyce ul Bohater w Warszawy 67 tel 89 763 50 50 fax 89 763 50 51 www pwkey pl e mail pwkey onet pl...

Reviews: