Initialization Procedure
Caution: This procedure is intended for initial installation only. Performing the
following steps will erase the database and load the default values.
9.04. To initialize the system following installation:
1) Set the power 0/1 switch to off, '0' position. (Refer to Figure 5) The
P.L. indicator lamp (red) is off.
2) Set system DIP switch element 1 to OFF.
3) Set the memory battery disconnect selector switch to OFF.
4) Set the power 0/1 switch to on, '1' position. Observe the following:
l
P.L. indicator lamp (red) is on. (Refer to Figure 5)
l
Memory protection indicator off as switch is off. (Refer to Figure 14)
l
Micro-processor scan indicator is flashing.
l
Trunk idle/busy status indicators are off.
5) Set system DIP switch element 1 to ON.
6) Set the memory battery disconnect selector switch to ON (up).
Memory protection indicator lamp (red) is on.
Battery Backup Connection
WARNING! Improper battery connections will damage the power supply. Ensure
that the proper polarity is maintained when connecting the battery cable
leads to power supply terminal pair + BATTERY -.
9.05. To connect the battery backup to the system following installation:
1) Set the power 0/1 switch to off, '0' position. (Refer to Figure 5) The P.L. indicator
lamp (red) is off.
2) At the previously installed battery pack, connect the cables at the battery pack
and connect the leads at ter BATTERY - on power supply unit located at
the bottom of the main cabinet. Check the battery leads polarity at the battery
and make sure the polarity is matched at the terminals (black = negative and red
= positive). Route the cables through an open slot on the side of the cabinet.