INSTALLATION
STEP 3
Connect Linears
1. Before mounting a linear with flexible connectors, determine the direction for the flexible connector and use
one of the right angled end covers to hold the wires in place. Omit the cover if flexible connector is threaded
through the mounting surface.
2. Snap products into mounting brackets such that input end of first luminaire is nearest to the controller. If it is
difficult to align the brackets to the product, make sure the bracket screw is not so tight that it cannot rotate or
slide up and down within the vertical slot.
3. Connect linears to each other.
4. Use cable and adapters where appropriate. Use adapters when connecting from a segment to a cable.
5. When connecting to the adapters, use the wiring identification to feed-through the signals appropriately.
6. If the standard design was purchased with straight connectors, adapters will always be used to make right
angle connections as shown in Figure A. If the custom ordering option with flexible connectors was purchased,
the flexible connectors from the linear segments will plug directly into each other as shown in Figure B.
Position 4
Black | COM
Position 3
Purple | DATA+
Position 1
Red | V+
Position 2
White | DATA-
Position 1
Red | V+
Position 2
White | DATA-
Position 4
Black | COM
Position 3
Purple | DATA+
Figure A
Figure B
1/5 in
(5 mm)
Strip Length:
10 |
LS0
INSTALLATION GUIDE
P/N 3662707 Rev A
© 2022 Lutron Electronics Co., Inc. All rights reserved.