4. Installation and assembly
Mains connection
Compressor
Wall bracket
Control unit
Mains connection compressor
Connecting socket for floating contact
Connection valve block (incl. floating switch)
Connection external signal generator
Compressed air connection valve block
Connection compressed air sensor
Elbow for connection compressed air hose
Quick-action coupling
4. 11 Installation control unit and compressor
Please note that an empty conduit (DN 100) must be laid to
accommodate the connecting lines between tank and con-
trol unit (see 4.7).
General notes
CAUTION: KESSEL recommends to commission a spe-
cialist electrical firm to execute the electrical connec-
tions. Only put the plant into operation after it has been
completely assembled. The plant may not be connected
to the mains while connection work is ongoing.
Control unit and compressor must be assembled in a frost-
protected, flood-proof and dry room. Pay attention to a
backwater-protected assembly!
Pay attention that the room in which the compressor will be
installed is well-ventilated. An adequate air circulation must
be ensured, in particular for equipment that is to be accom-
modated inside an external control cabinet so as to protect
the compressor against overheating.
A cool ambient temperature ensures a long service life for
diaphragms and valves.
The compressor should not be operated in a dusty environ-
ment. Overheating caused by clogged filters shortens the
service life of diaphragms and filters.
The compressor is to be protected against direct solar ra-
diation, snow and frost. The aspirated ambient air must be
free of flammable or aggressive gases or fumes.
The hose line must be laid as short and as straight as possible
between control unit and tank. Changes in direction must be
implemented via long curves instead of narrow bends.
The compressor must be placed upstream of the control
unit in frost-free areas on a suitable pedestal or bracket to
avoid any possible damage. Above the control to place the
compressor during installation in frost-free areas on a suita-
ble base or a console in order to avoid any damage. During
assembly within an outer cabinet of the compressor must
be installed below the control unit and to connect.
Assembly on an instable basis may give rise to bothersome
noises due to vibrations.
The compressor must be assembled horizontally to prevent
a one-sided load on the diaphragms and thus a shortened
service life of the components.
The compressor should fully rest on all 4 rubber feet and
may not wobble.
Summary of Contents for InnoClean PLUS EW 10
Page 2: ...2 ...
Page 40: ...12 CE Konformitätserklärung Leistungserklärung 40 ...
Page 85: ...85 12 Certificat de conformité declaration de performance ...
Page 130: ...12 Declaration of performance conformity 130 ...
Page 175: ...175 12 Deklaracja zgodności ...
Page 176: ...176 12 Deklaracja zgodności ...
Page 220: ...220 12 Dichiarazione di conformità CE ...
Page 221: ...221 12 Dichiarazione di conformità CE ...
Page 265: ...265 12 Verklaring van conformiteit ...
Page 266: ...266 12 Verklaring van conformiteit ...
Page 273: ...273 Verrohrung Tuyauteries Pipework Rury Tubazioni Leidingen ...
Page 274: ...Verrohrung Tuyauteries Pipework Rury Tubazioni Leidingen 274 France ...
Page 275: ...Verrohrung Tuyauteries Pipework Rury Tubazioni Leidingen France Retour de boues ...