Installation and operating manual
43
010-700_01
3. Technical data
Comfort Plus 230 V
Comfort Plus 400V
Maximum power at switching output
(at cos Phi = 1)
1.4
2.3
1.5
4.3
6.9
Nominal current range* A
4.0 - 6.3 A
6.3 - 10 A
2.5 - 4.0 A
4.0 - 6.3 A
6.3 - 10 A
Weight
4.0 kg
3.8 kg
Dimensions (LxWxD), mm
380 x 280 x 130
Operating voltage
230 V; 50 Hz
400 V AC / 50Hz
Standby power
5W
Potential-free contact
max. 42 V DC / 0.5 A
Battery
2 x 9V 6LR614
Working temperature
0 - 40°C
Protective rating
IP 54
Protection class
I
Connection type
Earthed coupling/control unit
Direct connection
Type of fuse required Mono, A
C 16
C 16
C 16
C 20
Type of fuse required Duo*, A
C 16
C 20
C 32
RCD
30 mA
Protection class
I
* Duo systems have two pumps with identical technical data. The respective control units are available in different power levels (of the motor protection switch).