EN
Display text
Possible cause
Remedial measure
|Power outage|
Power supply has failed.
Miniature fuse of the unit (S1) has
tripped.
Power supply has failed, circuit
breaker has tripped.
Main switch is defective - mains
supply cable interrupted.
none - general power outage.
Check fuse.
Check main switch.
Check mains cable. Deliberate
switching off, shut down control unit
(
see "Switch on and off", page 52
|Temperature error 1a
or
2a|
Self-resetting temperature monitoring
has tripped.
Self-resetting - the pump starts again
automatically when the motor has
cooled down. The error message is
acknowledged automatically. Replace
the pump if the temperature error occurs
frequently.
|Temperature error 1b
or
2b
|
NON self-resetting temperature moni-
toring has tripped.
NON self-resetting - the pump remains
inactive, even after the motor has
cooled down. It is necessary to switch
off and switch on again the control unit.
Replace the pump if the temperature
error occurs frequently.
56 / 204
Installation and operating manual
010-532_06
Summary of Contents for Aqualift F Comfort 400V Series
Page 18: ...DE 4 7 Anschlusspl ne Aqualift Comfort Mono 18 204 Einbau und Betriebsanleitung 010 532_07...
Page 84: ...FR Aqualift Comfort Duo 84 204 Instructions de pose et d utilisation 010 532_06...
Page 100: ...FR 0 3 Importation de param tres 100 204 Instructions de pose et d utilisation 010 532_06...
Page 118: ...IT Aqualift Comfort Duo 118 204 Istruzioni per l installazione e l uso 010 532_06...
Page 151: ...4 7 Aansluitschema s Aqualift Comfort Mono NL 010 532_06 Inbouw en montagehandleiding 151 204...
Page 152: ...NL Aqualift Comfort Duo 152 204 Inbouw en montagehandleiding 010 532_06...
Page 185: ...4 7 Schematy po cze Aqualift Comfort Mono PL 010 532_06 Instrukcja zabudowy i obs ugi 185 204...
Page 186: ...PL Aqualift Comfort Duo 186 204 Instrukcja zabudowy i obs ugi 010 532_06...
Page 203: ...010 532_07 203 204...