background image

25

5. Warranty

1. In the case that a KESSEL product is de-

fective, KESSEL has the option of repai-
ring or replacing the product. If the pro-
duct remains defective after the second
attempt to repair or replace the product or
it is economically unfeasible to repair or
replace the product, the customer has the
right to cancel the order / contract or re-
duce  payment  accordingly.  KESSEL
must be notified immediately in writing of
defects in a product. In the case that the
defect is not visible or difficult to detect,
KESSEL must be notified immediately in
writing of the defect as soon as it is di-
scovered. If the product is repaired or re-
placed,  the  newly  repaired  or  replaced
product  shall  receive  a  new  warranty
identical to that which the original (defec-
tive) product was granted. The term de-
fective product refers only to the product

or part needing repair or replacement and
not  necessarily  to  the  entire  product  or
unit. KESSEL products are warranted for
a period of 24 month. This warranty pe-
riod begins on the day the product is ship-
ped  form  KESSEL  to  its  customer.  The
warranty only applies to newly manufac-
tured  products.  Additional  information
can be found in section 377 of the HGB.

In addition to the standard warranty, KES-
SEL offers an additional 20 year warranty
on the polymer bodies of class I / II fuel
separators,  grease  separators,  inspec-
tion chambers, wastewater treatment sy-
stems and rainwater storage tanks. This
additional warranty applies to the water-
tightness, usability and structural sound-
ness of the product.
A requirement of this additional warranty
is  that  the  product  is  properly  installed

and operated in accordance with the valid
installation and user's manual as well as
the corresponding norms / regulations.

2. Wear  and  tear  on  a  product  will  not  be

considered a defect. Problems with pro-
ducts resulting from improper installation,
handling or maintenance will also be con-
sidered a defect.

Note: 

Only  the  manufacturer  may  open

sealed components or screw connections.
Otherwise, the warranty may become null
and void

01.06.2010

4. Inspection and Maintenance

Caution: 
After any service or repair work, make
sure that the system is back in opera-
tional condition by testing the flap with
the flap close button as well as closing
and  locking  the  manually  operated
backwater flap. Final step is to make
sure both the motorized and the ma-
nually operated backwater flap are in
the open position.

4.5    Purpose  of  the  emergency  closure
flap

The    emergency  closure  lever  can  be
used  to  completely  lock  the  manually
operated backwater flap.  When this flap

is locked no backwater will pass through
the backwater valve but at the same time
to fixtures connected to the Staufix® FKA
can  be  used  since  the  flap  is  shut. The
manually operated backwater flap can be
closed before leaving the home / building
prior to the drainage fixtures connected to
the FKA not being used for an extended
period of time (for example before leaving
for vacation). 

If the manually operated closure flap is
locked prior to vacation, it is critical to
re-open the closure lever as soon as
you  return  to  the  home  /  building.
Make sure that when the manual lever
is re-opened that there is no backwa-
ter condition.

Illustr. 16

Manually operated closure lever in the 
closed / locked position.

Summary of Contents for 83100.10 S/X

Page 1: ...sicherheit auch bei Stromausfall Bei R ckstau automatische Verriegelung Einfaches Auswechseln von Verschlei teilen Integrierter Einfachr ckstauverschluss f r stromlosen Betrieb w hrend der Bauphase Op...

Page 2: ...en Zur Aufrechterhaltung der Betriebsf hig keit ist die Anlage entsprechend DIN EN 13564 zu inspizieren und zu warten Wir empfehlen den Anschluss des beilie genden Wartungsvertrages mit Ihrem In stall...

Page 3: ...en werden Auslie ferzustand Bitte schlie en Sie erst bei Inbetriebnah me des KESSEL R ckstauautomaten Staufix FKA die elektrischen Anlagen komponenten Motor Sonde und Schalt ger t an Bis dahin sind di...

Page 4: ...auf ausreichend Abstand zur Wand f r Wartungsarbeiten zu achten 3 1 KESSEL Staufix FKA zum Einbau in die Bodenplatte Best Nr 83100S X 83125 S X 83150 S X 83200 S X bzw Komfort Best Nr 84100 S X 84125...

Page 5: ...s Aufsatzst ck ist beim Einstecken in das Verl ngerungss st ck auf das erforderliche Ma zu k rzen Achtung Beim Einbau von mehr als zwei Zwi schenst cken ist die Zug nglichkeit f r Wartungsarbeiten am...

Page 6: ...ungsst ck Best Nr 83071 Mit dem Verl ngerungsst ck aus Wartungsgr nden sind h chstens 2 Verl ngerungsst cke in einem Verbau zu verwenden ist die Flanschh he individuell einstellbar Das Aufsatzst ck is...

Page 7: ...uf hren Entfernen von Schmutz und Ab lagerungen Pr fen von Dichtungen und Dicht fl chen auf einwandfreien Zu stand ggf Austausch der Dich tungen siehe Abb 9 11 Kontrolle der Mechanik der be weglichen...

Page 8: ...rauben entfernen Die Sonde aus dem Deckel ziehen Die Sonde in Wasser ein tauchen Der Betriebsverschluss muss schlie en die optische und akustische Warneinrichtung mu ansprechen Sobald die Sonde aus de...

Page 9: ...scheider Fett abscheider Sch chte Kleinkl ranlagen und Regenwasserzisternen auf 20 Jahre bez glich Beh lter Dies bezieht sich auf die Dichtheit Gebrauchstauglichkeit und statische Sicherheit Vorausset...

Page 10: ...appe 80034 Haube 83031 bergangsst ck 83032 Pr ftrichter 70214 Dichtungsset f r Deckel Zulauf und Auslauf 70318 a b c FKA zum Einbau in die Bodenplatte Art Nr 83 100S X 83 125S X 83 150 S X 83 200S X b...

Page 11: ..._______________________________________________________ Adresse __________________________________________________________ Telefon Telefax __________________________________________________________ KE...

Page 12: ...12 Notizen...

Page 13: ...___________________ _______________________________________________________________________________________________________ Die Inbetriebnahme und Einweisung wird durchgef hrt durch Firma Adresse Ansp...

Page 14: ...Notizen 14...

Page 15: ...15...

Page 16: ...R ckstauverschl sse K Hebeanlagen K Abl ufe Duschrinnen K Abscheider Fettabscheider l Benzin Koaleszenzabscheider St rkeabscheider Sinkstoffabscheider K Kleinkl ranlagen K Sch chte K Regenwassernutzun...

Page 17: ...ional even during power outages Automatic backwater flap closure during backwater Staufix FKA also offer powerless backwater protection during the building phase no power supply to building Upgradable...

Page 18: ...he system it should be ins pected and maintained according to DIN EN 13564 We recommend that a service and main tenance contract is signed by a professio nal licensed service company During backwater...

Page 19: ...otor optical probe and control unit should not be connected until the system is commissioned after the major con struction phase of the building is comple te It is important that the electrical com po...

Page 20: ...r servi ce maintenance or repair is possible Caution Make sure that the backwater valve is installed in the proper direction and is not in stalled backwards KESSEL backwater val ves are equipped with...

Page 21: ...tion gaskets are supplied with the 83071 and should be properly lu bricated as stated previously In order to reach the properly installation height when using extension section s it may be re quired t...

Page 22: ...en sion sections should be used to assure proper access to the backwater valve for service or repair It may be required that the upper section is shortened to meet on site installation heights require...

Page 23: ...sure lever lubricate if necessary Check to make sure the system is water tight and in proper operating condition by performing the function sealing test see Chapter 4 3 Optical sensor should be cleane...

Page 24: ...est plug is firmly screwed to assure that the entire backwater valve cover is water tight Re open the motorized backwater flap by pressing the flap close button which will re open the flap 4 4 Check o...

Page 25: ...A requirement of this additional warranty is that the product is properly installed and operated in accordance with the valid installation and user s manual as well as the corresponding norms regulati...

Page 26: ...Protective cover dust cover 83031 Intermediate section 83032 Test funnel 70214 Gasket set for cover inlet and outlet 70318 a b c Staufix FKA for concrete slab installation Article Num bers 83100S X 83...

Page 27: ...tracted plumbing company __________________________________________________________ Address __________________________________________________________ Telephone Fax ___________________________________...

Page 28: ...28 Notizen...

Page 29: ...the enclosed operating instructions Initial operation and instruction were not carried out The client person responsible for initial operation was handed the following components and or product compon...

Page 30: ...Notice 30...

Page 31: ...31...

Page 32: ...ifting Stations and pumps K Drains and shower channels K Separators Grease Separators Oil Fuel Coalescence Separators Starch Separators Sediment Separators K Septic Systems K Inspection Chambers K Rai...

Page 33: ...bazioni continue Sicurezza di funzionamento anche in caso di interruzione di corrente Bloccaggio automatico in caso di riflusso Facile sostituzione dei particolari soggetti a usura Chiusura antiriflus...

Page 34: ...pezionato e manutenuto conf DIN EN 13564 Consigliamo di stipulare il contratto di ma nutenzione accluso con l azienda installa trice In presenza di riflusso o pericolo di riflusso non si devono esegui...

Page 35: ...o della consegna Solo alla messa in funzione dell impianto antiriflusso automatico Staufix FKA KESSEL collegare le componenti elettri che dell impianto motore sonda e cen tralina Fino a quel momento l...

Page 36: ...mpianto antiriflusso auto matico assicurare una distanza sufficiente dalla parete per i lavori di manutenzione 3 1 Staufix FKA KESSEL per il montag gio nella piastra di fondazione n ord 83100S X 83125...

Page 37: ...zioni Per l inserimento nella prolunga ac corciare il rialzo fino a ottenere la misura necessaria Attenzione In caso di montaggio di pi di due raccor di intermedi l accesso all FKA per i lavori di ma...

Page 38: ...lata individualmente Il rialzo deve essere eventualmente accorciato fino Pumpfix F Staufix FKA Staufix SWA Controlfix KES SEL Set di guarnizioni n art 83023 Prolunga n art 83071 Raccordo intermedio DN...

Page 39: ...tenuta eventualmente sostituzione delle guarnizioni vedi ill 9 11 controllo della meccanica degli or gani di tenuta mobili eventualmen te ingrassare constatazione della tenuta della chi usura d eserci...

Page 40: ...le viti Estrarre la sonda dal co perchio Immergere la sonda in acqua La chiusura d esercizio deve chiudere e il dispositivo di avvertimento ottico e acusti co deve attivarsi Non appena la sonda viene...

Page 41: ...ad anni 20 il periodo di garanzia per i separatori a coalescen za olio benzina separatore di grassi pozzetti fosse biologiche e serbatoi di acqua piovana in merito al solo serba toio Questo si riferi...

Page 42: ...031 Raccordo 83032 Imbuto di prova 70214 Set di guarnizioni per coperchio entrata e uscita 70318 a b c FKA per l installazione nella piastra di fondazione n art 83100S X 83125S X 83150 S X 83200S X op...

Page 43: ...______________________________________________________ Telefono Fax __________________________________________________________ N commissione KESSEL Persona autorizzata alla presa in consegna _________...

Page 44: ...44 Note...

Page 45: ..._____________________________________________ _______________________________________________________________________________________________________ La messa in funzione e l addestramento vengono ese...

Page 46: ...Note 46...

Page 47: ...47...

Page 48: ...ollevamento K Scarichi K Separatori Separatori di grassi Separatori di coalescenza olii e benzine Separatori di amidi Separatori di sedimenti K Trattamento delle acque reflue K Pozzetti di ispezione K...

Reviews: