Mähraupe HyCut
Maintenance
DE
2021-01-27
40 / 65
Safety guards (covers)
Interval
When commissioning, when turning on the machine
Scope
Visual inspection for integrity
Inspector
Operating personnel
Measures to
take in the
event of a
malfunction
•
Block off the danger zone
•
Carry out any repairs
Emergency stop button
Interval
When turning on the system and then once every four years as
part of the electro-technical test in accordance with BGV A3
[Regulation A3 of the Employer’s Liability Insurance
Association].
Scope
Operative readiness
Inspector
Operating personnel
Measures to
take in the
event of a
malfunction
•
Do not put the machine into operation
•
Disconnect the system from the mains and secure it
against being turned on again
•
Have the repairs carried out by a qualified electrician
7.3.2
Daily inspection
Personnel:
•
Private and commercial operators
Protective equipment:
•
Protective workwear
•
Protective gloves
•
Protective eyewear
The planning, execution and documentation of inspections must be performed by
the operator and in accordance with all applicable laws and regulations.
In order to ensure a safe operation of the machine, all safety devices must be
checked:
The following aspects must be checked each day:
•
Before each use, all safety elements and moving parts must be checked for
wear.
•
Check the engine oil level before commissioning the machine.
•
Check the air filter for contamination, blow the filter clean from the inside out
or replace it if it is heavily contaminated or damaged (see Chapter 7.5
Cleaning the air filter on Page 46).