10. Trouble shooting
Go to the search systematically for an error occurring. Please use the
following table and diagrams for electrical systems.If you can not ix
the error yourself, you should contact our customer service
Note the following points:
- The more precise description of the error, the quicker and better we
can help you.
- Keep the wiring diagram for electrics ready.
- Enter the serial number and the machine type
electric motor does not run:
- electric cable, or switch defect
-> change defect part
- Fuse for the main power line defect -> change fuse
- Emergency stop is active -> Pull it out
Reversing-Star Delta switch is not in „0“ position -> Put the knob in „0“
position
- One phase is missing (undervoltage) ->Check the power supply
The electric motor switches off:
- Motor protection switch has released. -> Reduce the blade feed or
its cutting depth
Floor saw does not lift or lower:
- Check the chassis, clean the spindle
Noncircular wear of the saw blade:
- Check the langed shaft.-> Check the bearings. Tigthen them.
High wear of the segments:
- Small quantity of water. -> Open the ball valve. Hose is creased. Fix
it
- Wrong speciication. -> Use another typ of blade
- Reduce the cutting depth