for sine and triangle, Repeat (initial/
repeat)

#

 - Display

Display Settings:: Graphic Display
(

meters

/graphics, background (

black

/

white/monoblack/blue/green/lt.green/
lt.blue), Protect Entry (

independent

/bipo-

lar) Waveform Stop (

output OFF

/User

Option), Key Press beep (

On

/Off/Error

only)

$

 - Analog Remote Setup

Analog Remote Settings: Reference input
(

internal

/external/external reference

level), protect limit (

Internal

/External/Les-

serLimit), external mode (

disable/

enable)

%

 - General Setup

Interface Settings: 

*RST set Output (

on

/off), 

GPIB Settings: Language (

SCPI

/CIIL),

GPIB address (default = 

6

),  Device

clear (

SCPI

/MATE) 

Serial Settings: Baudrate (

Off

/9600/

19200/38400), Xon/Xoff (

disable

/

enable), prompt (

disabled/echo/

enabled/enab+echo)

LAN Settings: IP Address, IP MASK,
AUTO IP 

ON

, DHCP 

ON

, Name and

index (MDNS name)

Max/Min Settings: for voltage mode: +Volt-
age max, –Voltage min, ±CProtect max/
min; for current mode: +Current max,
–Current min, ±VProtect max/min

Load Type: 

Active

/Resistive/Battery,

Remote On-off: (disabled/high is off/low is
off/high is on/low is on/LowPulseOff)

Standby Pin Operation: 

LowPulse

, HighI-

sOn, LowIsOn, HighIsOff, LowIsOff, Dis-
abled

Revisions/Test: (Tests: display, keypad,
LAN, interface, serial, analog and output)

Calibration: Voltage, Current and External
and Controls calibration. Shows Firmware
versions for Display, Serial, GPIB, LAN
and analog.

Power-up Settings: Mode (

Voltage

/Cur-

rent/External), Main channel Reference
(

Internal

/External/ExtlRefLev), main set-

ting, Protection: Type (

Internal

/External/

LesserLimit), Voltage Limit (current mode),
Current Level (voltage mode), output 

ON

/

OFF

Password

Password Settings: Menu protection
(Interface/Max-Min/Load/Test/Calibra-
tion/Power-up/Keypad @ local/Key-
pad@power-up), Save Display Change
(Enable/

Disable

), Passwords (Unpro-

tected/Main/Admin1/Admin2)

Series/Parallel: Configuration (Standalone/
Parallel/Series/Master 2X2/Master 3X2);
for parallel or series: Unit Type (Stand-
alone/1 to+4/Slave #1 to #4) and
Configuration: shows Series or Parallel).

FIGURE 5.  POWER-UP SCREEN SHOWING GRAPHIC METERS

HOW TO MODIFY A PARAMETER. 

First access the parameter by accessing the proper
menu as described above. To modify a parameter
listed in a menu or submenu, proceed as follows:

1. Highlight the parameter using the 

Y

 and 

U

 

keys.

2. When the desired choice is highlighted, press 

!

to modify the active setting. The choices are dis-

played with the active setting highlighted. In the
case of numerals, the units digit is highlighted. 

To change a numeric setting, press the num-
ber keys, then press 

ENTER

 to program the

numbers entered. Use the 

CLEAR key

 to

clear numbers entered and start over. The

ADJUST 

control can also be used to incre-

VOLTAGE
 SOURCE

0.0402

0.0000

ANALOG VOLTMETER

DIGITAL VOLTMETER

ANALOG AMMETER

DIGITAL AMMETER

HIGHLIGHT TO CHANGE

LOCAL/REMOTE

OPERATING

INFORMATION

SOFTWARE

FUNCTION KEY
DESCRIPTIONS

STATUS

ACTIVE SETTINGS

MESSAGES

VOLTAGE

0000

0.

Summary of Contents for BOP 10-100ME

Page 1: ...siderations and operating instructions including an Installation Operation Summary which includes hyperlinked references to detailed procedures but which can be printed as a handy reference The BOP 1K...

Page 2: ...on After careful unpacking inspect for shipping damage before attempting to operate Perform the Load Connec tions on page 5 If any indication of damage is found file an immediate claim with the respon...

Page 3: ...e four feet first rack must provide support at the rear Optional slides may be used Leave the front and rear panels clear of obstruc tions to ensure adequate cooling Allow a minimum of 7 8 in above an...

Page 4: ...4 228 1692 REV 9 062119 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 www kepcopower com email hq kepcopower com 1 FIGURE 1 BOP OUTPUT CHARACTERISTICS...

Page 5: ...odels only Connects BOP power supply to GPIB bus SNC 488 2 IEEE 488 Cable 4 meter longs For MG models only Connects BOP power supply to GPIB bus SNC 488 4 Interconnection Kits for parallel series conf...

Page 6: ...Port see Figure 3 provides for an external trigger input for use with SCPI TRG and TRIG commands Refer to Operator s manual for details GPIB CONNECTIONS MG SUFFIX Your computer must have a GPIB interf...

Page 7: ...AND INDICATORS RS 232 CONNECTIONS Connect the BOP 1KW to a modem using a Null Modem patch cable at the RS 232 port located on the rear panel See Figure 3 A Null Modem cable is not required for older...

Page 8: ...Y 11355 U S A TEL 718 461 7000 FAX 718 767 1102 www kepcopower com email hq kepcopower com FIGURE 3 BOP 1KW SERIES REAR PANEL VIEW LINKS INSTALLED FOR LOCAL SENSING FIGURE 4 LOAD CONNECTION A LOCAL SE...

Page 9: ...list and pressing the View Mod ify function key Menus and submenus will display a list of parameters with the top one highlighted The func tion key assignments can vary but generally offer the followi...

Page 10: ...on Shows Firmware versions for Display Serial GPIB LAN and analog Power up Settings Mode Voltage Cur rent External Main channel Reference Internal External ExtlRefLev main set ting Protection Type Int...

Page 11: ...ponding protection limit The main channel is determined by the MODE key in local mode which alternately selects either Voltage mode or Current mode or by SCPI com mand in digital remote mode The prote...

Page 12: ...rrent max min value and press to change it Software limits are absolute values do not use minus sign for nega tive limits Use number keys to change the set ting then to save 4 When complete press to s...

Page 13: ...g the power supply to load connections Resistive This mode as the name suggests is useful for resistive loads Table 6 indicates how the power supply responds to a command to go from Output ON to OFF V...

Page 14: ...stops energy flow during the OFF state Table 6 indicates how the power supply responds to a command to go from Output ON to OFF CONFIGURE LOAD TYPE To configure press from the power up screen then hi...

Page 15: ...power com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 1 OF 2 20 000 508 00 21 439 544 54 22 800 579 11 21 564 547 73 22 000 558 79 23 863 606 12 18 235 463 16 18 985 482 21 1 470...

Page 16: ...UE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 www kepcopower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 2 OF 2 SLIDES TRAVEL DISTANCE 23 000 584 2 22 000 558...

Reviews: