TK-2402(V)/2402/2406/2407
28
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
6. DQT
Deviation
*Note
1) TEST CH: Center
2) Deviation meter fi lter
LPF: 3kHz
HPF: OFF
3) PTT: ON
Deviation
meter
Oscilloscope
ANT
FPU
0.35kHz
±40Hz
7. QT
Deviation
*Note
1) TEST CH: Center
2) Deviation meter fi lter
LPF: 3kHz
HPF: OFF
3) PTT: ON
0.35kHz
±40Hz
8. DTMF
Deviation
*Note
1) TEST CH: Center
2) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
3) PTT: ON
1.5kHz
±50Hz
9. MSK
Deviation
*Note
1) TEST CH: Center
2) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
3) PTT: ON
1.5kHz
±50Hz
*Note (for the Max Dev, DQT Dev, QT Dev, DTMF Dev and MSK Dev):
1) If select the item without (Wide) or (Narrow), the alignment will be align according to Narrow Band. Wide band will automatically update by
calculation using Narrow band value.
2) If select the item with (Wide) or (Narrow),
(a) If wide band is selected, the alignment only will be done for wide band.
(b) If Narrow band is selected, the alignment only will be done for Narrow band.
Receiver Section
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
1. Sensitivity
(Semiauto-
matic)
1) TEST CH: Low, Center, High
(3 points)
SSG otuput : –90dBm
AF Freq : 1kHz
Mod Dev : 1.5kHz
SSG
Oscilloscope
Audio
Analyzer
ANT
FPU
Press [Start]
(Auto tuning)