TK-2402(V)/2402/2406/2407
5
REALIGNMENT
4. Wireless Clone Mode
4-1. Outline
“Wireless Clone Mode” copies the transceiver data to an-
other transceiver.
The dealer can copy the transceiver data to another
transceiver even without the use of a personal computer.
4-2. Example
The transceiver can copy the programming data to one or
more transceivers via RF communication.
The clone source and clone target/s must be in wireless
clone mode.
4-3. Operation
1. To switch the clone target/s to Wireless Clone mode,
press and hold the [PTT] and [side2] keys while turning
the transceiver power ON.
2. Wait for 2 seconds. The LED will light orange and the
transceiver will announce “Clone”.
3. Select a channel table number using Side1 (increment
channel table) and Side2 (decrement channnel table)
keys.
4. To switch the clone source to wireless clone mode, press
and hold the [PTT] and [side2] keys while turning the
transceiver power ON.
5. Wait for 2 seconds. The LED will light orange and the
transceiver will announce “Clone”.
6. Select the same channel table number as the clone
target/s.
7. Press [PTT] on the clone source to begin data transmis-
sion.
When the clone target starts to receive data, the LED will
light green.
When the clone source fi nishes sending data, a “confi r-
mation” tone will sound.
If data transmission fails while cloning, an “error” tone will
sound from the target unit.
8. If the cloning fails, no data will be available in the target
unit when it is returned to User mode.
9. When the cloning is successful, the target unit’s “Scan”
and “Key lock” functions will return to their default values
(Scan = OFF, Key lock = OFF).
Note:
• The dealer can clone data to two or more transceivers by
repeating the above procedures.
• If the transceivers wireless clone Mode is confi gured as
“Disabled”, the transceiver cannot enter Clone mode.
• The table shown below will cover the frequency tables
used for wireless cloning.
• Wireless clone mode cannot be entered in battery low
state.
• A unit cannot be a “Source Unit” if it is unprogrammed. If
[PTT] is pressed, an “error” tone will sound.
• Once a unit is set to be the source, it cannot be a target
after the data has been transmitted. This protects the
data in the source unit.
• Electronic interface may cause a failure in data transfer
during Wireless Clone, such as when waveforms or elec-
tromagnetics are being performed at the workbench.
• Wireless clone mode can be used ONLY by the au-
thorized service personnel.
• The wireless clone mode setting must be confi gured
as “Disable” before being delivered to the end-user.
• To clone, replace the antenna from both the source
transceiver and the target transceiver with a dummy
load.
• The transmit output power is automatically set to
Low in clone mode.
• Clone frequency table
No.
Operating frequency 136~174 (MHz)
1
136.150
2
138.150
3
140.150
4
142.150
5
144.150
6
146.150
7
148.150
8
150.150
9
152.150
10
154.150
11
156.150
12
158.150
13
160.150
14
162.150
15
164.150
16
166.150
17
168.150
18
170.150
19
172.150
20
174.150
Summary of Contents for TK-2402