background image

V

BENNETT® TRIM TAB ADAPTOR

WITH NMEA2000®, CAN BUS

AND RS485 RTU MODBUS INTERFACES 

PART NUMBERS: 5801

USER MANUAL

Revision 1.0.1

Summary of Contents for 5801

Page 1: ...V BENNETT TRIM TAB ADAPTOR WITH NMEA2000 CAN BUS AND RS485 RTU MODBUS INTERFACES PART NUMBERS 5801 USER MANUAL Revision 1 0 1...

Page 2: ......

Page 3: ...2 1 2 Product Features 2 2 Installation 3 2 1 Unpacking the box 3 2 2 Mounting the unit 3 2 3 Connecting the Deutsch Plug 4 2 4 Unit Switch Settings 5 3 Calibration 6 4 Maintenance 7 5 Technical Speci...

Page 4: ...o achieve the best results 1 1 FIRMWARE REVISION The information in this manual corresponds to firmware revision 1 1 4 1 2 PRODUCT FEATURES The Offshore Dynamics 5801 Bennett Trim Tab Adaptor has the...

Page 5: ...he following items in the 5801 shipping box 1 x 5801 Bennett Trim Tab Adaptor 1 x 5801 User Manual This document 3 x 5801 R Trim Tab Remote 2 2 MOUNTING THE UNIT The unit should be mounted to a flat s...

Page 6: ...UTSCH PLUG The unit is connected to the sensors and the communications interfaces via the 12 way Deutsch plug according to the following connection table Pin Number Connection 1 Modbus B 2 Modbus A 3...

Page 7: ...and 1 stop bit Please refer to Modbus specification for further information Modbus Commands The 5801 Trim Tab Adaptor identifies as slave 48 0x30 and supports one command 0x3 Read Holding Registers An...

Page 8: ...Power up the device Press the calibrate button so that the white calibration LED illuminates Actuate each sender between it s highest and lowest positions so the 5801 can learn where these limits are...

Page 9: ...they may remove paint or markings or may corrode the enclosure or seals Ensure that the unit is secure using the mounting holes on the device and cannot be moved relative to the mounting surface Chec...

Page 10: ...cations NMEA2000 Parameter Group Numbers PGNs Modbus RS885 RTU Memory Locations Parameter Comment Accuracy 2 No of Inductive sensors Up to 3 Type PGN No PGN Name Monitor PGN130576 Trim Tab Status Prot...

Page 11: ...anel mounted Parameter Value IEC 60954 Classification Protected Degree of Protection IP65 Operating Temperature 25 C to 50 C Storage Temperature 40 C to 70 C Relative Humidity 93 RH 40 per IEC60945 8...

Page 12: ...ew Milton Hampshire BH25 6RH United Kingdom Tel 44 0 1425 610022 Fax 44 0 1425 614794 Email sales osukl com Web www osukl com Copyright 2016 Offshore Dynamics Ltd All rights reserved Our policy is one...

Page 13: ...SEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL OFFSHORE DYNAMICS AGGREGATE LIABILITY...

Page 14: ...12 of 13 OFFSHORE DYNAMICS PRODUCT MAP 8...

Reviews: